Estimation of the reliability of measurements of motion ranges in knee joint with respect to various measurements techniques
Gespeichert in:
Deutscher übersetzter Titel: | Die Schätzung der Zuverlässigkeit von Messungen des Bewegungsradius im Kniegelenk in Bezug auf unterschiedliche Messmethoden |
---|---|
Autor: | Szulc, Pawel M.; Maczynski, Josek; Marecki, Bogustaw |
Erschienen in: | Sport Kinetics '97 : theories of human motor performance and their reflections in practice. Vol. 2: Posters. Fifth International Scientific Conference of the International Association of Sport Kinetics common with the Section "Sportmotorik" of the German Association for Sport Science (dvs) and the Institute of Sport Science of Otto-von-Guericke-University of Magdeburg ; Magdeburg |
Veröffentlicht: | Hamburg: Czwalina (Verlag), 1998, S. 107-111, Lit. |
Herausgeber: | Deutsche Vereinigung für Sportwissenschaft |
Forschungseinrichtung: | Universität Magdeburg / Institut für Sportwissenschaft ; International Association of Sport Kinetics ; Deutsche Vereinigung für Sportwissenschaft / Sektion Sportmotorik |
Format: | Literatur (SPOLIT) |
Publikationstyp: | Sammelwerksbeitrag |
Medienart: | Gedruckte Ressource |
Sprache: | Englisch |
Schlagworte: | |
Online Zugang: | |
Erfassungsnummer: | PU200707001857 |
Quelle: | BISp |
TY - COLL AU - Szulc, Pawel M. A2 - Szulc, Pawel M. A2 - Maczynski, Josek A2 - Marecki, Bogustaw DB - BISp DP - BISp KW - Biomechanik KW - Flexion KW - Goniometrie KW - Kniegelenk KW - Messgenauigkeit KW - Messgerät KW - Messverfahren KW - Untersuchung, vergleichende LA - eng PB - Czwalina CY - Hamburg TI - Estimation of the reliability of measurements of motion ranges in knee joint with respect to various measurements techniques TT - Die Schätzung der Zuverlässigkeit von Messungen des Bewegungsradius im Kniegelenk in Bezug auf unterschiedliche Messmethoden PY - 1998 N2 - An attempt has been undertaken in order to explain the differences between goniometric and electrogoniometric measurements which occur in living subjects. The selection of the measuring points was verified by using the photographic method. Errors in measurement resulting from the shift of the goniometer arms perpendicular to the axes of the long segments, were verified. Einleitung SP - S. 107-111 BT - Sport Kinetics '97 : theories of human motor performance and their reflections in practice. Vol. 2: Posters. Fifth International Scientific Conference of the International Association of Sport Kinetics common with the Section "Sportmotorik" of the German Association for Sport Science (dvs) and the Institute of Sport Science of Otto-von-Guericke-University of Magdeburg ; Magdeburg M3 - Gedruckte Ressource ID - PU200707001857 ER -