Errors in alignment of center of pressure and foot coordinates affect predicted lower extremity torques

Gespeichert in:
Bibliographische Detailangaben
Deutscher übersetzter Titel:Fehler in der Abstimmung des Druckzentrums und der Fusskoordinaten beeinflussen die Kraftmomentberechnungen an der unteren Extremitaet
Autor:McCaw, Steven T.; DeVita, Paul
Erschienen in:Journal of biomechanics
Veröffentlicht:28 (1995), 8, S. 985-988, Lit.
Format: Literatur (SPOLIT)
Publikationstyp: Zeitschriftenartikel
Medienart: Gedruckte Ressource Elektronische Ressource (online)
Sprache:Englisch
ISSN:0021-9290, 1873-2380
DOI:10.1016/0021-9290(94)00151-S
Schlagworte:
Online Zugang:
Erfassungsnummer:PU199506101666
Quelle:BISp
TY  - JOUR
AU  - McCaw, Steven T.
A2  - McCaw, Steven T.
A2  - DeVita, Paul
DB  - BISp
DP  - BISp
KW  - Biomechanik
KW  - Ganganalyse
KW  - Kinematik
KW  - Kraftmessplatte
KW  - Kraftmessung
KW  - Messfehler
KW  - Messgenauigkeit
KW  - Messverfahren
KW  - Stützphase
LA  - eng
TI  - Errors in alignment of center of pressure and foot coordinates affect predicted lower extremity torques
TT  - Fehler in der Abstimmung des Druckzentrums und der Fusskoordinaten beeinflussen die Kraftmomentberechnungen an der unteren Extremitaet
PY  - 1995
N2  - The purpose of the study was to quantify the effect of errors in spatial alignment between the center of pressure recorded from a force platform and the coordinates of the foot recorded from film on resultant joint torques in the lower extremity during the stance phase of gait. Two-dimensional kinematic and kinetic data from eight subjects performing walking and running were analyzed using inverse dynamics with the obtained center of pressure values and with +/- 0.5 and +/- 1.0 cm shifts in the anteroposterior location of the center of pressure under the support foot. Shifting the center of pressure posteriorly increased the flexor (dorsiflexor) torques at the hip and ankle and decreased the extensor (plantarflexor) torques at these joints. This shift also caused an increase in the extensor and a decrease in the flexor torques at the knee. Shifting the center of pressure anteriorly caused the opposite effects at each joint. The +/- 0.5 and +/- 1.0 cm shifts in the location of the center of pressure caused, on average, 7 and 14% changes, respectively, in maximum joint torque and angular impulse values. Relative transition times between flexor and extensor torques were either increased or decreased, on average, by 7 and 13%, respectively for the two conditions over all trials. Based on these results, it is concluded that due to potential errors in the spatial alignment of kinetic and kinematic data, joint torques in the literature on gait should be considered as approximations of the true values.       Verf.-Referat
L2  - https://dx.doi.org/10.1016/0021-9290(94)00151-S
DO  - 10.1016/0021-9290(94)00151-S
SP  - S. 985-988
SN  - 0021-9290
JO  - Journal of biomechanics
IS  - 8
VL  - 28
M3  - Gedruckte Ressource
M3  - Elektronische Ressource (online)
ID  - PU199506101666
ER  -