Genucom knee analysis system: reproducibility and database development

Gespeichert in:
Bibliographische Detailangaben
Deutscher übersetzter Titel:Genucom Kniegelenkanalysesystem: Reproduzierbarkeit und Datenbank-Entwicklung
Autor:Highgenboten, Carl L.; Jackson, Allen; Meske, Neil B.
Erschienen in:Medicine and science in sports and exercise
Veröffentlicht:22 (1990), 5, S. 713-717, Lit.
Format: Literatur (SPOLIT)
Publikationstyp: Zeitschriftenartikel
Medienart: Gedruckte Ressource
Sprache:Englisch
ISSN:0195-9131, 1530-0315
Schlagworte:
Online Zugang:
Erfassungsnummer:PU199302047044
Quelle:BISp
id PU199302047044
bisp-collection db
format Literatur
last_indexed 2008-05-16T09:46:43Z
first_indexed 2003-12-30T14:26:37Z
publication_source BISp
subformat Zeitschriftenartikel
hierarchy_top_id JO00000000986
hierarchy_parent_id JOI199000050000986
hierarchy_top_title Medicine and science in sports and exercise
hierarchy_parent_title Medicine and science in sports and exercise, 1990, 5
is_hierarchy_id PU199302047044
is_hierarchy_title Genucom knee analysis system: reproducibility and database development
hierarchy_sequence 0713
recordtype bisparticle
publishDate 1990
publishDate_facet 1990
language eng
title Genucom knee analysis system: reproducibility and database development
spellingShingle Genucom knee analysis system: reproducibility and database development
Diagnostische Verfahren
Gelenkfunktion
Gelenkinstabilität
Kniegelenk
Kniegelenkdiagnostik
Sportmedizin
title_sort genucom knee analysis system reproducibility and database development
title_short Genucom knee analysis system: reproducibility and database development
title_alt Genucom Kniegelenkanalysesystem: Reproduzierbarkeit und Datenbank-Entwicklung
title_alt_lang deu
media_type Gedruckte Ressource
city Indianapolis (Ind.)
abstract The Genucom is a relatively new computerized system that performs a multidimensional analysis of knee laxity. Therefore, the purposes of the present investigation were twofold: 1) to estimate the reproducibility of the testing system in its ability to obtain similar test values on the same test subject within a back-to-back two-test protocol and 2) to develop a database of normal values as a standard against which values of suspected ligament injury can be compared to reliably determine whether, in fact, ligament injury has occurred. In the reproducibility phase of the study, 20 subjects were tested in two trials each of eight tests, yielding 20 separate test values per trial, accounting for each angle of flexion and plane of force tested. Both legs were tested, providing an N of 40. Test-retest correlations of the two trials and dependent t-tests indicated that the Genucom provided generally stable and reproducible results. In the normal value database phase of the study, 218 different subjects were given one trial of the same eight tests. Testing of both legs provided an N > 400. Means and standard deviations were calculated for each test. Verf.-Referat
abstract_lang eng
abstract_type abstract
author2 Highgenboten, Carl L.
Jackson, Allen
Meske, Neil B.
author_facet Highgenboten, Carl L.
Jackson, Allen
Meske, Neil B.
author2-role Autor
Autor
Autor
author2-authorityid


author_author_facet Highgenboten, Carl L.
Jackson, Allen
Meske, Neil B.
author2-synonym


author2_hierarchy_facet 0/Autor/
1/Autor/Highgenboten, Carl L./
0/Autor/
1/Autor/Jackson, Allen/
0/Autor/
1/Autor/Meske, Neil B./
issn 0195-9131
1530-0315
spelling 0195-9131
1530-0315
603994-7
Diagnostische Verfahren
Gelenkfunktion
Gelenkinstabilität
Kniegelenk
Kniegelenkdiagnostik
Sportmedizin
diagnostic procedures
joint function
joint instability
knee-joint
knee-joint diagnostics
sports medicine
Knie
Genu varum
Knieaussenband
Kniebandverletzung
Kniegelenkoperation
Knieinnenband
Lig. collaterale mediale
Ligamentum collaterale mediale
Genu valgum
Gelenkinsuffizienz
Diagnose
Diagnosemethode
Diagnostik
Untersuchungsdiagnostik
Medizin
Geschichte der Medizin
Untersuchung, sportmedizinische
Wasserdampf
Lachman-Test
articular instability
instability of a joint
articular function
Genucom knee analysis system: reproducibility and database development
PU199302047044
199302047044
zdb 603994-7
location_hierarchy_facet 0/USA/
1/USA/Indiana/
topic Diagnostische Verfahren
Gelenkfunktion
Gelenkinstabilität
Kniegelenk
Kniegelenkdiagnostik
Sportmedizin
topic_facet Diagnostische Verfahren
Gelenkfunktion
Gelenkinstabilität
Kniegelenk
Kniegelenkdiagnostik
Sportmedizin
topic_en diagnostic procedures
joint function
joint instability
knee-joint
knee-joint diagnostics
sports medicine
topic_en_facet diagnostic procedures
joint function
joint instability
knee-joint
knee-joint diagnostics
sports medicine
synonym Knie
Genu varum
Knieaussenband
Kniebandverletzung
Kniegelenkoperation
Knieinnenband
Lig. collaterale mediale
Ligamentum collaterale mediale
Genu valgum
Gelenkinsuffizienz
Diagnose
Diagnosemethode
Diagnostik
Untersuchungsdiagnostik
Medizin
Geschichte der Medizin
Untersuchung, sportmedizinische
Wasserdampf
Lachman-Test
synonym_en articular instability
instability of a joint
articular function
journal_facet Medicine and science in sports and exercise
container_title Medicine and science in sports and exercise
container_volume 22
container_issue 5
container_start_page S. 713-717
has_references 1
institution BISp
journal_fac JO00000000986
journal_year 1990
journal_issue 5
_version_ 1810308170660184064
score 13,263368