Next-generation low-cost motion capture systems can provide comparable spatial accuracy to high-end systems

Gespeichert in:
Bibliographische Detailangaben
Deutscher übersetzter Titel:Kostengünstige Bewegungserfassungssysteme der nächsten Generation liefern eine vergleichbare dreidimensionale Präzision wie High-End-Systeme
Autor:Thewlis, Dominic; Bishop, Christopher R.; Daniell, Nathan; Paul, Gunther
Erschienen in:Journal of applied biomechanics
Veröffentlicht:29 (2013), 1, S. 112-117, Lit.
Format: Literatur (SPOLIT)
Publikationstyp: Zeitschriftenartikel
Medienart: Gedruckte Ressource Elektronische Ressource (Datenträger)
Sprache:Englisch
ISSN:1065-8483, 1543-2688
DOI:10.1123/jab.29.1.112
Schlagworte:
Online Zugang:
Erfassungsnummer:PU201310006984
Quelle:BISp
TY  - JOUR
AU  - Thewlis, Dominic
A2  - Thewlis, Dominic
A2  - Bishop, Christopher R.
A2  - Daniell, Nathan
A2  - Paul, Gunther
DB  - BISp
DP  - BISp
KW  - Bewegungsanalyse
KW  - Bewegungslehre
KW  - Biomechanik
KW  - Ganganalyse
KW  - Kinematik
KW  - Messgerät
KW  - Sporttechnologie
KW  - Technologie
LA  - eng
TI  - Next-generation low-cost motion capture systems can provide comparable spatial accuracy to high-end systems
TT  - Kostengünstige Bewegungserfassungssysteme der nächsten Generation liefern eine vergleichbare dreidimensionale Präzision wie High-End-Systeme
PY  - 2013
N2  - The objective quantification of three-dimensional kinematics during different functional and occupational tasks is now more in demand than ever. The introduction of new generation of low-cost passive motion capture systems from a number of manufacturers has made this technology accessible for teaching, clinical practice and in small/medium industry. Despite the attractive nature of these systems, their accuracy remains unproved in independent tests. We assessed static linear accuracy, dynamic linear accuracy and compared gait kinematics from a Vicon MX-f20 system to a Natural Point OptiTrack system. In all experiments data were sampled simultaneously. We identified both systems perform excellently in linear accuracy tests with absolute errors not exceeding 1%. In gait data there was again strong agreement between the two systems in sagittal and coronal plane kinematics. Transverse plane kinematics differed by up to 3° at the knee and hip, which we attributed to the impact of soft tissue artifact accelerations on the data. We suggest that low-cost systems are comparably accurate to their high-end competitors and offer a platform with accuracy acceptable in research for laboratories with a limited budget. Verf.-Referat
L2  - https://dx.doi.org/10.1123/jab.29.1.112
DO  - 10.1123/jab.29.1.112
SP  - S. 112-117
SN  - 1065-8483
JO  - Journal of applied biomechanics
IS  - 1
VL  - 29
M3  - Gedruckte Ressource
M3  - Elektronische Ressource (Datenträger)
ID  - PU201310006984
ER  -