Reliabilita testování stoje na jedné noze při opakovaném měření
Gespeichert in:
Deutscher übersetzter Titel: | Reliabilität des Flamingotests bei wiederholter Messung |
---|---|
Englischer übersetzter Titel: | Intra-session reliability of flamingo test in adults |
Autor: | Baláš, Jiří; Zahálka, František |
Erschienen in: | Česká kinantropologie |
Veröffentlicht: | 15 (2011), 3, S. 165-171, Lit. |
Format: | Literatur (SPOLIT) |
Publikationstyp: | Zeitschriftenartikel |
Medienart: | Elektronische Ressource (online) Gedruckte Ressource |
Sprache: | Tschechisch |
ISSN: | 1211-9261 |
Schlagworte: | |
Online Zugang: | |
Erfassungsnummer: | PU201304002369 |
Quelle: | BISp |
id |
PU201304002369 |
---|---|
bisp-collection |
db |
format |
Literatur |
last_indexed |
2015-07-02T10:00:25Z |
first_indexed |
2013-04-02T13:39:16Z |
publication_source |
BISp |
subformat |
Zeitschriftenartikel |
hierarchy_top_id |
JO00000100278 |
hierarchy_parent_id |
JOI201100030100278 |
hierarchy_top_title |
Česká kinantropologie |
hierarchy_parent_title |
Česká kinantropologie, 2011, 3 |
is_hierarchy_id |
PU201304002369 |
is_hierarchy_title |
Reliabilita testování stoje na jedné noze při opakovaném měření |
hierarchy_sequence |
0165 |
recordtype |
bisparticle |
publishDate |
2011 |
publishDate_facet |
2011 |
language |
ces |
title |
Reliabilita testování stoje na jedné noze při opakovaném měření |
spellingShingle |
Reliabilita testování stoje na jedné noze při opakovaném měření Bewegungslehre Biomechanik Druckmessung Extremität, untere Gleichgewichtstest Gleichgewichtsvermögen Gleichgewichtsübung Koordinationstest Kraftmessplatte Messgerät Reliabilität Stehen Tensometrie Test, motorischer Test, psychomotorischer Testauswertung Testinterpretation |
title_sort |
reliabilita testování stoje na jedné noze při opakovaném měření |
title_short |
Reliabilita testování stoje na jedné noze při opakovaném měření |
title_alt |
Reliabilität des Flamingotests bei wiederholter Messung Intra-session reliability of flamingo test in adults |
title_alt_lang |
deu eng |
media_type |
Elektronische Ressource (online) Gedruckte Ressource |
city |
Prag |
spelling |
Praha 1211-9261 Bewegungslehre Biomechanik Druckmessung Extremität, untere Gleichgewichtstest Gleichgewichtsvermögen Gleichgewichtsübung Koordinationstest Kraftmessplatte Messgerät Reliabilität Stehen Tensometrie Test, motorischer Test, psychomotorischer Testauswertung Testinterpretation balance balance exercise balance test biomechanics coordination test force platform lower extremity measurement apparatus motor test movement theory pressure measurement psychomotor test reliability standing tensometry test evaluation test interpretation Fertigkeitstest Iowa-Brace-Test Test, lernzielorientierter Test, sensomotorischer Hocktest Stand Gleichgewicht Balanceübung Balancierübung Kraftplattform Messanlage Messinstrument Messeinrichtung Bewegungsforschung Bewegungstheorie Bein Beinversehrter Beinigkeit Beinamputierter Bewegung, physikalische Merkmal, biomechanisches Biokinematik Prinzip, biomechanisches balance drill force plate gage movement science lower limb Reliabilita testování stoje na jedné noze při opakovaném měření PU201304002369 201304002369 |
abstract |
The aim of the study was to assess the intrasession reliability of flamingo tests during repeated measures on the pressure plate FootScan. Twenty adults between 20–49 years of age volunteered in the study. The one leg stand lasted for 63 s and three measurements for the left and right leg with a 1 minute rest were recorded. The trajectory of the center of pressure (COP) was measured. The reliability was assessed by intraclass coefficient of correlation (ICC), coefficient of variation (CV) and standard error of measurement (SEM). The ICC 2,1 for the trajectory of COP ranged between 0.82-0.90 for the left and 0.87–0.88 for the right leg. Despite high coefficients of relative reliability, the absolute reliability was lowered. CV for the left leg standing was 13.7% and 9.7% for the right leg standing, SEM 17% for the left and 15% for the right leg standing. However, CV and SEM involve only 68% of the true scores. The CV for 95% range was 26,8% for the left and 19,2% for the right standing, SEM 35% for the left and 31% for the right standing. The measure-ment of one leg standing indicates the level of stability or balance whose are influenced by the number of hardly controlled processes. The current results of the reliability confirm this statement. Verf.-Referat |
abstract_lang |
eng |
abstract_type |
author |
author2 |
Baláš, Jiří Zahálka, František |
author_facet |
Baláš, Jiří Zahálka, František |
author2-role |
Autor Autor |
author2-authorityid |
P159904 P189071 |
author_author_facet |
Baláš, Jiří Zahálka, František |
author2-synonym |
|
author2_hierarchy_facet |
0/Autor/ 1/Autor/Baláš, Jiří/ 0/Autor/ 1/Autor/Zahálka, František/ |
url |
http://www.ceskakinantropologie.cz/index.php/TestJournal/article/view/92/115 |
url-type |
fulltext |
url-free |
1 |
free_access |
1 |
issn |
1211-9261 |
location_hierarchy_facet |
0/Tschechische Republik/ |
topic |
Bewegungslehre Biomechanik Druckmessung Extremität, untere Gleichgewichtstest Gleichgewichtsvermögen Gleichgewichtsübung Koordinationstest Kraftmessplatte Messgerät Reliabilität Stehen Tensometrie Test, motorischer Test, psychomotorischer Testauswertung Testinterpretation |
topic_facet |
Bewegungslehre Biomechanik Druckmessung Extremität, untere Gleichgewichtstest Gleichgewichtsvermögen Gleichgewichtsübung Koordinationstest Kraftmessplatte Messgerät Reliabilität Stehen Tensometrie Test, motorischer Test, psychomotorischer Testauswertung Testinterpretation |
topic_en |
balance balance exercise balance test biomechanics coordination test force platform lower extremity measurement apparatus motor test movement theory pressure measurement psychomotor test reliability standing tensometry test evaluation test interpretation |
topic_en_facet |
balance balance exercise balance test biomechanics coordination test force platform lower extremity measurement apparatus motor test movement theory pressure measurement psychomotor test reliability standing tensometry test evaluation test interpretation |
synonym |
Fertigkeitstest Iowa-Brace-Test Test, lernzielorientierter Test, sensomotorischer Hocktest Stand Gleichgewicht Balanceübung Balancierübung Kraftplattform Messanlage Messinstrument Messeinrichtung Bewegungsforschung Bewegungstheorie Bein Beinversehrter Beinigkeit Beinamputierter Bewegung, physikalische Merkmal, biomechanisches Biokinematik Prinzip, biomechanisches |
synonym_en |
balance drill force plate gage movement science lower limb |
journal_facet |
Česká kinantropologie |
container_title |
Česká kinantropologie |
container_volume |
15 |
container_issue |
3 |
container_start_page |
S. 165-171 |
has_references |
1 |
institution |
BISp |
journal_fac |
JO00000100278 |
journal_year |
2011 |
journal_issue |
3 |
_version_ |
1791512311790305280 |
score |
13,560151 |