Comparison of detected values Footscan – Kistler
Gespeichert in:
Deutscher übersetzter Titel: | Ein Vergleich der von Footscan und Kistler festgestellten Werte |
---|---|
Autor: | Pánková, Barbora; Kubový, Petr; Fanta, Ondřej; Jelen, Karel |
Erschienen in: | Acta Universitatis Carolinae / Kinanthropologica |
Veröffentlicht: | 47 (2011), 2, S. 208-214, Lit. |
Format: | Literatur (SPOLIT) |
Publikationstyp: | Zeitschriftenartikel |
Medienart: | Gedruckte Ressource Elektronische Ressource (online) |
Sprache: | Englisch |
ISSN: | 1212-1428, 0323-0511, 2336-6052 |
Schlagworte: | |
Online Zugang: | |
Erfassungsnummer: | PU201210007029 |
Quelle: | BISp |
id |
PU201210007029 |
---|---|
bisp-collection |
db |
format |
Literatur |
last_indexed |
2022-04-27T11:37:58Z |
first_indexed |
2012-10-29T12:37:56Z |
publication_source |
BISp |
subformat |
Zeitschriftenartikel |
hierarchy_top_id |
JO00000000034 |
hierarchy_parent_id |
JOI201100020000034 |
hierarchy_top_title |
Acta Universitatis Carolinae / Kinanthropologica |
hierarchy_parent_title |
Acta Universitatis Carolinae / Kinanthropologica, 2011, 2 |
is_hierarchy_id |
PU201210007029 |
is_hierarchy_title |
Comparison of detected values Footscan – Kistler |
hierarchy_sequence |
0208 |
recordtype |
bisparticle |
publishDate |
2011 |
publishDate_facet |
2011 |
language |
eng |
title |
Comparison of detected values Footscan – Kistler |
spellingShingle |
Comparison of detected values Footscan – Kistler Biomechanik Druckverteilung Kraftmessplatte Messgenauigkeit Messverfahren Schritt Stützphase Untersuchung, vergleichende |
title_sort |
comparison of detected values footscan – kistler |
title_short |
Comparison of detected values Footscan – Kistler |
title_alt |
Ein Vergleich der von Footscan und Kistler festgestellten Werte |
title_alt_lang |
deu |
media_type |
Gedruckte Ressource Elektronische Ressource (online) |
city |
Prag |
spelling |
Praha 1212-1428 0323-0511 2336-6052 1382383-8 Biomechanik Druckverteilung Kraftmessplatte Messgenauigkeit Messverfahren Schritt Stützphase Untersuchung, vergleichende biomechanics comparative study force platform measurement accuracy measurement method pressure distribution step support phase Bewegung, physikalische Merkmal, biomechanisches Biokinematik Prinzip, biomechanisches Druckaufnahme Kraftplattform Genauigkeit Bestimmung Messmethode Messung Vergleich force plate stride comparative investigation Comparison of detected values Footscan – Kistler PU201210007029 201210007029 |
abstract |
Commercially available devices objectifying the amount of pressure under the foot are often different in accuracy and reliability of results. The aim of this pilot study was to compare output values of plantar pressure within one step generated by the system Kistler and Footscan. Software synchronization of both devices was performed and it was found from the subsequent evaluation that the values of forces obtained from the device Footscan are lower than these obtained from the Kistler system. This linear correlation may be only used in the evaluation phase of the maximum loaded foot (peak area); in the phase of lightening foot from the ground the system Footscan is burdened with a significant error of measurement, probably due to nonlinearity in the mechanical properties of the surface of the measuring plate. Verf.-Referat |
abstract_lang |
eng |
abstract_type |
abstract |
author2 |
Pánková, Barbora Kubový, Petr Fanta, Ondřej Jelen, Karel |
author_facet |
Pánková, Barbora Kubový, Petr Fanta, Ondřej Jelen, Karel |
author2-role |
Autor Autor Autor Autor |
author2-authorityid |
P172164 |
author_author_facet |
Pánková, Barbora Kubový, Petr Fanta, Ondřej Jelen, Karel |
author2-synonym |
|
author2_hierarchy_facet |
0/Autor/ 1/Autor/Pánková, Barbora/ 0/Autor/ 1/Autor/Kubový, Petr/ 0/Autor/ 1/Autor/Fanta, Ondřej/ 0/Autor/ 1/Autor/Jelen, Karel/ |
url |
https://karolinum.cz/casopis/auc-kinanthropologica/rocnik-47/cislo-2/clanek-764 |
url-type |
fulltext |
url-free |
1 |
free_access |
1 |
issn |
1212-1428 0323-0511 2336-6052 |
zdb |
1382383-8 |
location_hierarchy_facet |
0/Tschechische Republik/ |
topic |
Biomechanik Druckverteilung Kraftmessplatte Messgenauigkeit Messverfahren Schritt Stützphase Untersuchung, vergleichende |
topic_facet |
Biomechanik Druckverteilung Kraftmessplatte Messgenauigkeit Messverfahren Schritt Stützphase Untersuchung, vergleichende |
topic_en |
biomechanics comparative study force platform measurement accuracy measurement method pressure distribution step support phase |
topic_en_facet |
biomechanics comparative study force platform measurement accuracy measurement method pressure distribution step support phase |
synonym |
Bewegung, physikalische Merkmal, biomechanisches Biokinematik Prinzip, biomechanisches Druckaufnahme Kraftplattform Genauigkeit Bestimmung Messmethode Messung Vergleich |
synonym_en |
force plate stride comparative investigation |
journal_facet |
Acta Universitatis Carolinae / Kinanthropologica |
container_title |
Acta Universitatis Carolinae / Kinanthropologica |
container_volume |
47 |
container_issue |
2 |
container_start_page |
S. 208-214 |
has_references |
1 |
institution |
BISp |
journal_fac |
JO00000000034 |
journal_year |
2011 |
journal_issue |
2 |
_version_ |
1791514042741817344 |
score |
13,560151 |