Comparison of detected values Footscan – Kistler

Gespeichert in:
Bibliographische Detailangaben
Deutscher übersetzter Titel:Ein Vergleich der von Footscan und Kistler festgestellten Werte
Autor:Pánková, Barbora; Kubový, Petr; Fanta, Ondřej; Jelen, Karel
Erschienen in:Acta Universitatis Carolinae / Kinanthropologica
Veröffentlicht:47 (2011), 2, S. 208-214, Lit.
Format: Literatur (SPOLIT)
Publikationstyp: Zeitschriftenartikel
Medienart: Gedruckte Ressource Elektronische Ressource (online)
Sprache:Englisch
ISSN:1212-1428, 0323-0511, 2336-6052
Schlagworte:
Online Zugang:
Erfassungsnummer:PU201210007029
Quelle:BISp
id PU201210007029
bisp-collection db
format Literatur
last_indexed 2022-04-27T11:37:58Z
first_indexed 2012-10-29T12:37:56Z
publication_source BISp
subformat Zeitschriftenartikel
hierarchy_top_id JO00000000034
hierarchy_parent_id JOI201100020000034
hierarchy_top_title Acta Universitatis Carolinae / Kinanthropologica
hierarchy_parent_title Acta Universitatis Carolinae / Kinanthropologica, 2011, 2
is_hierarchy_id PU201210007029
is_hierarchy_title Comparison of detected values Footscan – Kistler
hierarchy_sequence 0208
recordtype bisparticle
publishDate 2011
publishDate_facet 2011
language eng
title Comparison of detected values Footscan – Kistler
spellingShingle Comparison of detected values Footscan – Kistler
Biomechanik
Druckverteilung
Kraftmessplatte
Messgenauigkeit
Messverfahren
Schritt
Stützphase
Untersuchung, vergleichende
title_sort comparison of detected values footscan – kistler
title_short Comparison of detected values Footscan – Kistler
title_alt Ein Vergleich der von Footscan und Kistler festgestellten Werte
title_alt_lang deu
media_type Gedruckte Ressource
Elektronische Ressource (online)
city Prag
spelling Praha
1212-1428
0323-0511
2336-6052
1382383-8
Biomechanik
Druckverteilung
Kraftmessplatte
Messgenauigkeit
Messverfahren
Schritt
Stützphase
Untersuchung, vergleichende
biomechanics
comparative study
force platform
measurement accuracy
measurement method
pressure distribution
step
support phase
Bewegung, physikalische
Merkmal, biomechanisches
Biokinematik
Prinzip, biomechanisches
Druckaufnahme
Kraftplattform
Genauigkeit
Bestimmung
Messmethode
Messung
Vergleich
force plate
stride
comparative investigation
Comparison of detected values Footscan – Kistler
PU201210007029
201210007029
abstract Commercially available devices objectifying the amount of pressure under the foot are often different in accuracy and reliability of results. The aim of this pilot study was to compare output values of plantar pressure ​​within one step generated by the system Kistler and Footscan. Software synchronization of both devices was performed and it was found from the subsequent evaluation that the values ​​of forces obtained from the device Footscan are lower than these obtained from the Kistler system. This linear correlation may be only used in the evaluation phase of the maximum loaded foot (peak area); in the phase of lightening foot from the ground the system Footscan is burdened with a significant error of measurement, probably due to nonlinearity in the mechanical properties of the surface of the measuring plate. Verf.-Referat
abstract_lang eng
abstract_type abstract
author2 Pánková, Barbora
Kubový, Petr
Fanta, Ondřej
Jelen, Karel
author_facet Pánková, Barbora
Kubový, Petr
Fanta, Ondřej
Jelen, Karel
author2-role Autor
Autor
Autor
Autor
author2-authorityid
P172164


author_author_facet Pánková, Barbora
Kubový, Petr
Fanta, Ondřej
Jelen, Karel
author2-synonym



author2_hierarchy_facet 0/Autor/
1/Autor/Pánková, Barbora/
0/Autor/
1/Autor/Kubový, Petr/
0/Autor/
1/Autor/Fanta, Ondřej/
0/Autor/
1/Autor/Jelen, Karel/
url https://karolinum.cz/casopis/auc-kinanthropologica/rocnik-47/cislo-2/clanek-764
url-type fulltext
url-free 1
free_access 1
issn 1212-1428
0323-0511
2336-6052
zdb 1382383-8
location_hierarchy_facet 0/Tschechische Republik/
topic Biomechanik
Druckverteilung
Kraftmessplatte
Messgenauigkeit
Messverfahren
Schritt
Stützphase
Untersuchung, vergleichende
topic_facet Biomechanik
Druckverteilung
Kraftmessplatte
Messgenauigkeit
Messverfahren
Schritt
Stützphase
Untersuchung, vergleichende
topic_en biomechanics
comparative study
force platform
measurement accuracy
measurement method
pressure distribution
step
support phase
topic_en_facet biomechanics
comparative study
force platform
measurement accuracy
measurement method
pressure distribution
step
support phase
synonym Bewegung, physikalische
Merkmal, biomechanisches
Biokinematik
Prinzip, biomechanisches
Druckaufnahme
Kraftplattform
Genauigkeit
Bestimmung
Messmethode
Messung
Vergleich
synonym_en force plate
stride
comparative investigation
journal_facet Acta Universitatis Carolinae / Kinanthropologica
container_title Acta Universitatis Carolinae / Kinanthropologica
container_volume 47
container_issue 2
container_start_page S. 208-214
has_references 1
institution BISp
journal_fac JO00000000034
journal_year 2011
journal_issue 2
_version_ 1791514042741817344
score 13,560151