Reproducibility of resting peripheral blood flow using strain gauge plethysmography
Gespeichert in:
Deutscher übersetzter Titel: | Reproduzierbarkeit von Ruhewerten der peripheren Durchblutung aus der Venenverschlussplethysmographie |
---|---|
Autor: | Fehling, P.C.; Arciero, P.J.; MacPherson, C.J.; Smith, D.L. |
Erschienen in: | International journal of sports medicine |
Veröffentlicht: | 20 (1999), 8, S. 555-559, Lit. |
Format: | Literatur (SPOLIT) |
Publikationstyp: | Zeitschriftenartikel |
Medienart: | Gedruckte Ressource Elektronische Ressource (online) |
Sprache: | Englisch |
ISSN: | 0172-4622, 1439-3964 |
DOI: | 10.1055/s-1999-8845 |
Schlagworte: | |
Online Zugang: | |
Erfassungsnummer: | PU199912403849 |
Quelle: | BISp |
id |
PU199912403849 |
---|---|
bisp-collection |
db |
format |
Literatur |
last_indexed |
2021-01-11T09:46:15Z |
first_indexed |
2001-07-24T13:51:30Z |
publication_source |
BISp |
subformat |
Zeitschriftenartikel |
hierarchy_top_id |
JO00000000664 |
hierarchy_parent_id |
JOI199900080000664 |
hierarchy_top_title |
International journal of sports medicine |
hierarchy_parent_title |
International journal of sports medicine, 1999, 8 |
is_hierarchy_id |
PU199912403849 |
is_hierarchy_title |
Reproducibility of resting peripheral blood flow using strain gauge plethysmography |
hierarchy_sequence |
0555 |
recordtype |
bisparticle |
publishDate |
1999 |
publishDate_facet |
1999 |
language |
eng |
title |
Reproducibility of resting peripheral blood flow using strain gauge plethysmography |
spellingShingle |
Reproducibility of resting peripheral blood flow using strain gauge plethysmography Diagnostische Verfahren Durchblutungsmessung Kreislauf, peripherer Reliabilität Reproduzierbarkeit Ruhewert Sportmedizin Venenverschlussplethysmographie |
title_sort |
reproducibility of resting peripheral blood flow using strain gauge plethysmography |
title_short |
Reproducibility of resting peripheral blood flow using strain gauge plethysmography |
title_alt |
Reproduzierbarkeit von Ruhewerten der peripheren Durchblutung aus der Venenverschlussplethysmographie |
title_alt_lang |
deu |
media_type |
Gedruckte Ressource Elektronische Ressource (online) |
city |
Stuttgart |
abstract |
The purposee of this study was to examine the intra-tester and inter-tester reliability of strain gauge plethysmography (SGP) using the Hokanson EC-5R plethysmograph among three investigators. An arterial inflow test was performed by each of the investigators on fifteen college-aged volunteers at the forearm and calf sites. Intra-tester reliability was assessed by analyzing three serial measurements obtained at both sites. Inter-tester reliability was assessed in two ways: first, by having the three investigators obtain and analyze their own recordings, and, second, by having all three investigators (Testers 1, 2, and 3) analyze SGP recordings obtained by the most experienced investigator (Tester 1). The mean coefficient of variation (CV) for the intra-tester analysis was similar at the forearm (4.9%) and calf (4.0%) sites. The inter-tester analysis revealed that there were no significant differences among the three testers at either site when investigators obtained and analyzed their own waveforms. The CV calculated from the means of the three investigators was greater at the forearm site (10.7%) than at the calf site (2.5%). Similarly, when Testers 2 and 3 analyzed Tester 1's waveforms there were no significant differences found among Testers at either site and the CV was less than when each investigator obtained his/her own waveforms. Strain gauge plethysmography blood flow measures obtained by experienced testers, under controlled laboratory conditions, are reproducible. The small variability in blood flow that exists is more attributable to variability in the acquisition of the waveforms than in the analysis of the waveforms. Verf.-Referat |
abstract_lang |
eng |
abstract_type |
author |
author2 |
Fehling, P.C. Arciero, P.J. MacPherson, C.J. Smith, D.L. |
author_facet |
Fehling, P.C. Arciero, P.J. MacPherson, C.J. Smith, D.L. |
author2-role |
Autor Autor Autor Autor |
author2-authorityid |
|
author_author_facet |
Fehling, P.C. Arciero, P.J. MacPherson, C.J. Smith, D.L. |
author2-synonym |
|
author2_hierarchy_facet |
0/Autor/ 1/Autor/Fehling, P.C./ 0/Autor/ 1/Autor/Arciero, P.J./ 0/Autor/ 1/Autor/MacPherson, C.J./ 0/Autor/ 1/Autor/Smith, D.L./ |
doi |
10.1055/s-1999-8845 |
spelling |
10.1055/s-1999-8845 0172-4622 1439-3964 IJSMD 603122-5 Diagnostische Verfahren Durchblutungsmessung Kreislauf, peripherer Reliabilität Reproduzierbarkeit Ruhewert Sportmedizin Venenverschlussplethysmographie blood-flow measurement diagnostic procedures peripheral circulation reliability reproducability resting value sports medicine venous-occlusion-plethysmography Ruhe Diagnose Diagnosemethode Diagnostik Untersuchungsdiagnostik Medizin Geschichte der Medizin Untersuchung, sportmedizinische Wasserdampf Reproducibility of resting peripheral blood flow using strain gauge plethysmography PU199912403849 199912403849 |
url |
https://dx.doi.org/10.1055/s-1999-8845 |
url-type |
fulltext |
url-free |
1 |
free_access |
1 |
issn |
0172-4622 1439-3964 |
coden |
IJSMD |
zdb |
603122-5 |
location_hierarchy_facet |
0/Deutschland/ 1/Deutschland/Baden-Württemberg/ |
topic |
Diagnostische Verfahren Durchblutungsmessung Kreislauf, peripherer Reliabilität Reproduzierbarkeit Ruhewert Sportmedizin Venenverschlussplethysmographie |
topic_facet |
Diagnostische Verfahren Durchblutungsmessung Kreislauf, peripherer Reliabilität Reproduzierbarkeit Ruhewert Sportmedizin Venenverschlussplethysmographie |
topic_en |
blood-flow measurement diagnostic procedures peripheral circulation reliability reproducability resting value sports medicine venous-occlusion-plethysmography |
topic_en_facet |
blood-flow measurement diagnostic procedures peripheral circulation reliability reproducability resting value sports medicine venous-occlusion-plethysmography |
synonym |
Ruhe Diagnose Diagnosemethode Diagnostik Untersuchungsdiagnostik Medizin Geschichte der Medizin Untersuchung, sportmedizinische Wasserdampf |
journal_facet |
International journal of sports medicine |
container_title |
International journal of sports medicine |
container_volume |
20 |
container_issue |
8 |
container_start_page |
S. 555-559 |
has_references |
1 |
institution |
BISp |
journal_fac |
JO00000000664 |
journal_year |
1999 |
journal_issue |
8 |
_version_ |
1799524749124042752 |
score |
13,242886 |