Reproducibility of resting peripheral blood flow using strain gauge plethysmography

Gespeichert in:
Bibliographische Detailangaben
Deutscher übersetzter Titel:Reproduzierbarkeit von Ruhewerten der peripheren Durchblutung aus der Venenverschlussplethysmographie
Autor:Fehling, P.C.; Arciero, P.J.; MacPherson, C.J.; Smith, D.L.
Erschienen in:International journal of sports medicine
Veröffentlicht:20 (1999), 8, S. 555-559, Lit.
Format: Literatur (SPOLIT)
Publikationstyp: Zeitschriftenartikel
Medienart: Gedruckte Ressource Elektronische Ressource (online)
Sprache:Englisch
ISSN:0172-4622, 1439-3964
DOI:10.1055/s-1999-8845
Schlagworte:
Online Zugang:
Erfassungsnummer:PU199912403849
Quelle:BISp
id PU199912403849
bisp-collection db
format Literatur
last_indexed 2021-01-11T09:46:15Z
first_indexed 2001-07-24T13:51:30Z
publication_source BISp
subformat Zeitschriftenartikel
hierarchy_top_id JO00000000664
hierarchy_parent_id JOI199900080000664
hierarchy_top_title International journal of sports medicine
hierarchy_parent_title International journal of sports medicine, 1999, 8
is_hierarchy_id PU199912403849
is_hierarchy_title Reproducibility of resting peripheral blood flow using strain gauge plethysmography
hierarchy_sequence 0555
recordtype bisparticle
publishDate 1999
publishDate_facet 1999
language eng
title Reproducibility of resting peripheral blood flow using strain gauge plethysmography
spellingShingle Reproducibility of resting peripheral blood flow using strain gauge plethysmography
Diagnostische Verfahren
Durchblutungsmessung
Kreislauf, peripherer
Reliabilität
Reproduzierbarkeit
Ruhewert
Sportmedizin
Venenverschlussplethysmographie
title_sort reproducibility of resting peripheral blood flow using strain gauge plethysmography
title_short Reproducibility of resting peripheral blood flow using strain gauge plethysmography
title_alt Reproduzierbarkeit von Ruhewerten der peripheren Durchblutung aus der Venenverschlussplethysmographie
title_alt_lang deu
media_type Gedruckte Ressource
Elektronische Ressource (online)
city Stuttgart
abstract The purposee of this study was to examine the intra-tester and inter-tester reliability of strain gauge plethysmography (SGP) using the Hokanson EC-5R plethysmograph among three investigators. An arterial inflow test was performed by each of the investigators on fifteen college-aged volunteers at the forearm and calf sites. Intra-tester reliability was assessed by analyzing three serial measurements obtained at both sites. Inter-tester reliability was assessed in two ways: first, by having the three investigators obtain and analyze their own recordings, and, second, by having all three investigators (Testers 1, 2, and 3) analyze SGP recordings obtained by the most experienced investigator (Tester 1). The mean coefficient of variation (CV) for the intra-tester analysis was similar at the forearm (4.9%) and calf (4.0%) sites. The inter-tester analysis revealed that there were no significant differences among the three testers at either site when investigators obtained and analyzed their own waveforms. The CV calculated from the means of the three investigators was greater at the forearm site (10.7%) than at the calf site (2.5%). Similarly, when Testers 2 and 3 analyzed Tester 1's waveforms there were no significant differences found among Testers at either site and the CV was less than when each investigator obtained his/her own waveforms. Strain gauge plethysmography blood flow measures obtained by experienced testers, under controlled laboratory conditions, are reproducible. The small variability in blood flow that exists is more attributable to variability in the acquisition of the waveforms than in the analysis of the waveforms. Verf.-Referat
abstract_lang eng
abstract_type author
author2 Fehling, P.C.
Arciero, P.J.
MacPherson, C.J.
Smith, D.L.
author_facet Fehling, P.C.
Arciero, P.J.
MacPherson, C.J.
Smith, D.L.
author2-role Autor
Autor
Autor
Autor
author2-authorityid



author_author_facet Fehling, P.C.
Arciero, P.J.
MacPherson, C.J.
Smith, D.L.
author2-synonym



author2_hierarchy_facet 0/Autor/
1/Autor/Fehling, P.C./
0/Autor/
1/Autor/Arciero, P.J./
0/Autor/
1/Autor/MacPherson, C.J./
0/Autor/
1/Autor/Smith, D.L./
doi 10.1055/s-1999-8845
spelling 10.1055/s-1999-8845
0172-4622
1439-3964
IJSMD
603122-5
Diagnostische Verfahren
Durchblutungsmessung
Kreislauf, peripherer
Reliabilität
Reproduzierbarkeit
Ruhewert
Sportmedizin
Venenverschlussplethysmographie
blood-flow measurement
diagnostic procedures
peripheral circulation
reliability
reproducability
resting value
sports medicine
venous-occlusion-plethysmography
Ruhe
Diagnose
Diagnosemethode
Diagnostik
Untersuchungsdiagnostik
Medizin
Geschichte der Medizin
Untersuchung, sportmedizinische
Wasserdampf
Reproducibility of resting peripheral blood flow using strain gauge plethysmography
PU199912403849
199912403849
url https://dx.doi.org/10.1055/s-1999-8845
url-type fulltext
url-free 1
free_access 1
issn 0172-4622
1439-3964
coden IJSMD
zdb 603122-5
location_hierarchy_facet 0/Deutschland/
1/Deutschland/Baden-Württemberg/
topic Diagnostische Verfahren
Durchblutungsmessung
Kreislauf, peripherer
Reliabilität
Reproduzierbarkeit
Ruhewert
Sportmedizin
Venenverschlussplethysmographie
topic_facet Diagnostische Verfahren
Durchblutungsmessung
Kreislauf, peripherer
Reliabilität
Reproduzierbarkeit
Ruhewert
Sportmedizin
Venenverschlussplethysmographie
topic_en blood-flow measurement
diagnostic procedures
peripheral circulation
reliability
reproducability
resting value
sports medicine
venous-occlusion-plethysmography
topic_en_facet blood-flow measurement
diagnostic procedures
peripheral circulation
reliability
reproducability
resting value
sports medicine
venous-occlusion-plethysmography
synonym Ruhe
Diagnose
Diagnosemethode
Diagnostik
Untersuchungsdiagnostik
Medizin
Geschichte der Medizin
Untersuchung, sportmedizinische
Wasserdampf
journal_facet International journal of sports medicine
container_title International journal of sports medicine
container_volume 20
container_issue 8
container_start_page S. 555-559
has_references 1
institution BISp
journal_fac JO00000000664
journal_year 1999
journal_issue 8
_version_ 1799524749124042752
score 13,242886