A comparison of power outputs on the Wingate test and on a test using an isokinetic device
Gespeichert in:
Deutscher übersetzter Titel: | Ein Vergleich der Leistungen beim Wingate-Test und bei einem Test mittels eines isokinetischen Geraets |
---|---|
Autor: | Baltzopoulos, Vasilios B.; Eston, R.G.; MacLaren, D. |
Erschienen in: | Ergonomics |
Veröffentlicht: | 31 (1988), Bd. 11, S. 1693-1699, Lit. |
Format: | Literatur (SPOLIT) |
Publikationstyp: | Zeitschriftenartikel |
Medienart: | Gedruckte Ressource |
Sprache: | Englisch |
ISSN: | 0014-0139, 1366-5847 |
Schlagworte: | |
Online Zugang: | |
Erfassungsnummer: | PU198910036223 |
Quelle: | BISp |
id |
PU198910036223 |
---|---|
bisp-collection |
db |
format |
Literatur |
last_indexed |
2004-06-28T16:29:38Z |
first_indexed |
2003-12-30T14:07:00Z |
publication_source |
BISp |
subformat |
Zeitschriftenartikel |
hierarchy_top_id |
JO00000000484 |
hierarchy_parent_id |
JOI1988d32d0000484 |
hierarchy_top_title |
Ergonomics |
hierarchy_parent_title |
Ergonomics, 1988, Bd. 11 |
is_hierarchy_id |
PU198910036223 |
is_hierarchy_title |
A comparison of power outputs on the Wingate test and on a test using an isokinetic device |
hierarchy_sequence |
1693 |
recordtype |
bisparticle |
publishDate |
1988 |
publishDate_facet |
1988 |
language |
eng |
title |
A comparison of power outputs on the Wingate test and on a test using an isokinetic device |
spellingShingle |
A comparison of power outputs on the Wingate test and on a test using an isokinetic device Diagnostische Verfahren Kapazität, anaerobe Leistungsdiagnostik Leistungstest Methodenvergleich Muskelkontraktion, isokinetische Sportmedizin Wingate-Test |
title_sort |
a comparison of power outputs on the wingate test and on a test using an isokinetic device |
title_short |
A comparison of power outputs on the Wingate test and on a test using an isokinetic device |
title_alt |
Ein Vergleich der Leistungen beim Wingate-Test und bei einem Test mittels eines isokinetischen Geraets |
title_alt_lang |
deu |
media_type |
Gedruckte Ressource |
city |
London |
abstract |
The Wingate test has been used as a major test of muscle power whereas isokinetic devices have been used to determine muscle strength. The aim of this study was to examine the relationships between the 30 s Wingate test and tests using repeated knee extensions/flexions on an isokinetic dynamometer (Akron). Ten females and eight males undertook a 30 s Wingate test, six maximal reciprocal contractions of the knee extensors and flexors in the isokinetic dynamometer, and a 30 s test of repeated maximal reciprocal contractions of the knee extensors and flexors. Five minutes after the 30 s tests a blood sample was taken for lactate determination. Significant correlations were obtained for the peak power output (PPO) between the Wingate test and the isokinetic extension and flexion tests. Significant correlations were also obtained for the fatigue index (FI) between the Wingate test and the 30 s isokinetic test. Fatigue index was defined as the decline in PPO over time. Values for PPO were significantly higher in the Wingate test than the corresponding extension and flexion values in the isokinetic maximum torque test. Post-exercise blood lactate concentrations were also significantly higher for the Wingate test than for the 30 s isokinetic test. There was a weak but significant correlation between blood lactate for the Wingate and 30 s isokinetic test. These results suggest that the isokinetic tests used in this study are useful measures of anaerobic power. Verf.-Referat |
abstract_lang |
eng |
abstract_type |
abstract |
author2 |
Baltzopoulos, Vasilios B. Eston, R.G. MacLaren, D. |
author_facet |
Baltzopoulos, Vasilios B. Eston, R.G. MacLaren, D. |
author2-role |
Autor Autor Autor |
author2-authorityid |
P76127 |
author_author_facet |
Baltzopoulos, Vasilios B. Eston, R.G. MacLaren, D. |
author2-synonym |
|
author2_hierarchy_facet |
0/Autor/ 1/Autor/Baltzopoulos, Vasilios B./ 0/Autor/ 1/Autor/Eston, R.G./ 0/Autor/ 1/Autor/MacLaren, D./ |
issn |
0014-0139 1366-5847 |
spelling |
0014-0139 1366-5847 ERGOA 1920-3 Diagnostische Verfahren Kapazität, anaerobe Leistungsdiagnostik Leistungstest Methodenvergleich Muskelkontraktion, isokinetische Sportmedizin Wingate-Test anaerobic capacity comparison of methods diagnostic procedures exercise test isokinetic muscle contraction performance diagnostics sports medicine Wingate test Leistungsfähigkeit, anaerobe Kapazität Vergleich Medizin Geschichte der Medizin Untersuchung, sportmedizinische Wasserdampf Diagnose Diagnosemethode Diagnostik Untersuchungsdiagnostik Leistungsbestimmung Leistungsdiagnose Leistungserfassung Leistungsfeststellung Trainingsdiagnostik Wingate Test method comparison A comparison of power outputs on the Wingate test and on a test using an isokinetic device PU198910036223 198910036223 |
coden |
ERGOA |
zdb |
1920-3 |
location_hierarchy_facet |
0/Großbritannien/ 1/Großbritannien/England/ |
topic |
Diagnostische Verfahren Kapazität, anaerobe Leistungsdiagnostik Leistungstest Methodenvergleich Muskelkontraktion, isokinetische Sportmedizin Wingate-Test |
topic_facet |
Diagnostische Verfahren Kapazität, anaerobe Leistungsdiagnostik Leistungstest Methodenvergleich Muskelkontraktion, isokinetische Sportmedizin Wingate-Test |
topic_en |
anaerobic capacity comparison of methods diagnostic procedures exercise test isokinetic muscle contraction performance diagnostics sports medicine Wingate test |
topic_en_facet |
anaerobic capacity comparison of methods diagnostic procedures exercise test isokinetic muscle contraction performance diagnostics sports medicine Wingate test |
synonym |
Leistungsfähigkeit, anaerobe Kapazität Vergleich Medizin Geschichte der Medizin Untersuchung, sportmedizinische Wasserdampf Diagnose Diagnosemethode Diagnostik Untersuchungsdiagnostik Leistungsbestimmung Leistungsdiagnose Leistungserfassung Leistungsfeststellung Trainingsdiagnostik Wingate Test |
synonym_en |
method comparison |
journal_facet |
Ergonomics |
container_title |
Ergonomics |
container_volume |
31 |
container_issue |
Bd. 11 |
container_start_page |
S. 1693-1699 |
has_references |
1 |
institution |
BISp |
journal_fac |
JO00000000484 |
journal_year |
1988 |
journal_issue |
Bd. 11 |
_version_ |
1810442426498678784 |
score |
12,752381 |