Laboratory evaluation of low-cost wearable sensors for measuring head impacts in sports

Gespeichert in:
Bibliographische Detailangaben
Deutscher übersetzter Titel:Laboruntersuchung kostengünstiger tragbarer Sensoren für die Messung von Krafteinwirkungen am Kopf im Sport
Autor:Tyson, Abigail M.; Duma, Stefan M.; Rowson, Steven
Erschienen in:Journal of applied biomechanics
Veröffentlicht:34 (2018), 4, S. 320-326, Lit.
Format: Literatur (SPOLIT)
Publikationstyp: Zeitschriftenartikel
Medienart: Elektronische Ressource (online) Gedruckte Ressource
Sprache:Englisch
ISSN:1065-8483, 1543-2688
DOI:10.1123/jab.2017-0256
Schlagworte:
Online Zugang:
Erfassungsnummer:PU201905003344
Quelle:BISp

Abstract des Autors

Advances in low-cost wearable head impact sensor technology provide potential benefits regarding sports safety for both consumers and researchers. However, previous laboratory evaluations are not directly comparable and do not incorporate test conditions representative of unhelmeted impacts. This study addresses those limitations. The xPatch by X2 Biosystems and the SIM-G by Triax Technologies were placed on a National Operating Committee on Standards for Athletic Equipment (NOCSAE) headform with a Hybrid III neck which underwent impact tests using a pendulum. Impact conditions included helmeted, padded impactor to bare head, and rigid impactor to bare head to represent long- and short-duration impacts seen in helmeted and unhelmeted sports. The wearable sensors were evaluated on their kinematic accuracy by comparing results to reference sensors located at the headform center of gravity. Statistical tests for equivalence were performed on the slope of the linear regression between wearable sensors and reference. The xPatch gave equivalent measurements to the reference in select longer-duration impacts, whereas the SIM-G had large variance leading to no equivalence. For the short-duration impacts, both wearable sensors underpredicted the reference. This error can be improved with increases in sampling rate from 1 to 1.5 kHz. Follow-up evaluations should be performed on the field to identify error in vivo.