Reliability of tensiomyography and myotonometry in detecting mechanical and contractile characteristics of the lumbar erector spinae in healthy volunteers
Gespeichert in:
Deutscher übersetzter Titel: | Zuverlässigkeit der Tensiomyographie und Myotonometrie bei der Erkennung mechanischer und kontraktiler Eigenschaften der Lendenwirbelsäule bei gesunden Freiwilligen |
---|---|
Autor: | Lohr, Christine; Braumann, Klaus-Michael; Reer, Rüdiger; Schröder, Jan; Schmidt, Tobias |
Erschienen in: | European journal of applied physiology |
Veröffentlicht: | 118 (2018), 7, S. 1349-1359, Lit. |
Format: | Literatur (SPOLIT) |
Publikationstyp: | Zeitschriftenartikel |
Medienart: | Elektronische Ressource (online) Gedruckte Ressource |
Sprache: | Englisch |
ISSN: | 1439-6319, 0301-5548 |
DOI: | 10.1007/s00421-018-3867-2 |
Schlagworte: | |
Online Zugang: | |
Erfassungsnummer: | PU201903002135 |
Quelle: | BISp |
id |
PU201903002135 |
---|---|
bisp-collection |
db |
format |
Literatur |
last_indexed |
2020-07-06T14:49:15Z |
first_indexed |
2019-03-20T14:27:42Z |
publication_source |
BISp |
subformat |
Zeitschriftenartikel |
hierarchy_top_id |
JO00000100345 |
hierarchy_parent_id |
JOI201800070100345 |
hierarchy_top_title |
European journal of applied physiology |
hierarchy_parent_title |
European journal of applied physiology, 2018, 7 |
is_hierarchy_id |
PU201903002135 |
is_hierarchy_title |
Reliability of tensiomyography and myotonometry in detecting mechanical and contractile characteristics of the lumbar erector spinae in healthy volunteers |
hierarchy_sequence |
1349 |
recordtype |
bisparticle |
publishDate |
2018 |
publishDate_facet |
2018 |
language |
eng |
title |
Reliability of tensiomyography and myotonometry in detecting mechanical and contractile characteristics of the lumbar erector spinae in healthy volunteers |
spellingShingle |
Reliability of tensiomyography and myotonometry in detecting mechanical and contractile characteristics of the lumbar erector spinae in healthy volunteers Kontraktionszeit Leistungsphysiologie Lendenwirbelsäule M. erector spinae Muskelkontraktion Myotonometrie Reliabilität Reproduzierbarkeit Sportmedizin Tensiomyographie Varianzanalyse |
title_sort |
reliability of tensiomyography and myotonometry in detecting mechanical and contractile characteristics of the lumbar erector spinae in healthy volunteers |
title_short |
Reliability of tensiomyography and myotonometry in detecting mechanical and contractile characteristics of the lumbar erector spinae in healthy volunteers |
title_alt |
Zuverlässigkeit der Tensiomyographie und Myotonometrie bei der Erkennung mechanischer und kontraktiler Eigenschaften der Lendenwirbelsäule bei gesunden Freiwilligen |
title_alt_lang |
deu |
media_type |
Elektronische Ressource (online) Gedruckte Ressource |
city |
Berlin |
abstract |
Purpose: Tensiomyography™ (TMG) and MyotonPRO® (MMT) are two non-invasive devices for monitoring muscle contractile and mechanical characteristics. This study aimed to evaluate the test–retest reliability of TMG and MMT parameters for measuring (TMG:) muscle displacement (Dm), contraction time (Tc), and velocity (Vc) and (MMT:) frequency (F), stiffness (S), and decrement (D) of the erector spinae muscles (ES) in healthy adults. A particular focus was set on the establishment of reliability measures for the previously barely evaluated secondary TMG parameter Vc.
Methods: Twenty-four subjects (13 female and 11 male, mean +/- SD, 38.0 +/- 12.0 years) were measured using TMG and MMT over 2 consecutive days. Absolute and relative reliability was calculated by standard error of measurement (SEM, SEM%), Minimum detectable change (MDC, MDC%), coefficient of variation (CV%) and intraclass correlation coefficient (ICC, 3.1) with a 95% confidence interval (CI).
Results: The ICCs for all variables and test–retest intervals ranged from 0.75 to 0.99 indicating a good to excellent relative reliability for both TMG and MMT, demonstrating the lowest values for TMG Tc and between-day MMT D (ICC < 0.90). Absolute reliability was suitable for all parameters (CV 2–8%) except for Dm (10–12%). Vc demonstrated to be the most reliable and repeatable TMG parameter (ICC > 0.95, CV < 8%).
Conclusion: The reliability for TMG Vc could be established successfully. Its further applicability needs to be confirmed in future studies. MMT was found to be more reliable on repeated testing than the two other TMG parameters Dm and Tc. |
abstract_lang |
eng |
abstract_type |
author |
author2 |
Lohr, Christine Braumann, Klaus-Michael Reer, Rüdiger Schröder, Jan Schmidt, Tobias |
author_facet |
Lohr, Christine Braumann, Klaus-Michael Reer, Rüdiger Schröder, Jan Schmidt, Tobias |
author2-role |
Autor Autor Autor Autor Autor |
author2-authorityid |
P377032 P1130 P2752 P25665 |
author_author_facet |
Lohr, Christine Braumann, Klaus-Michael Reer, Rüdiger Schröder, Jan Schmidt, Tobias |
author2-synonym |
Braumann, Michael ,Braumann, K.-M. Schroeder, Jan |
author2_hierarchy_facet |
0/Autor/ 1/Autor/Lohr, Christine/ 0/Autor/ 1/Autor/Braumann, Klaus-Michael/ 0/Autor/ 1/Autor/Reer, Rüdiger/ 0/Autor/ 1/Autor/Schröder, Jan/ 0/Autor/ 1/Autor/Schmidt, Tobias/ |
doi |
10.1007/s00421-018-3867-2 |
spelling |
10.1007/s00421-018-3867-2 1439-6319 0301-5548 EJAPC 124793-1 Kontraktionszeit Leistungsphysiologie Lendenwirbelsäule M. erector spinae Muskelkontraktion Myotonometrie Reliabilität Reproduzierbarkeit Sportmedizin Tensiomyographie Varianzanalyse contraction time exercise physiology lumbar spine m. erector spinae muscle contraction myotonometry reliability reproducability sports medicine tensiomyography variance analysis Medizin Geschichte der Medizin Untersuchung, sportmedizinische Wasserdampf Arbeitsphysiologie Physiologie Sportphysiologie Kontraktionsgeschwindigkeit Varianz physiology of exercise performance physiology erector muscle of spine contraction duration duration of contraction Reliability of tensiomyography and myotonometry in detecting mechanical and contractile characteristics of the lumbar erector spinae in healthy volunteers PU201903002135 201903002135 |
url |
https://dx.doi.org/10.1007/s00421-018-3867-2 |
url-type |
fulltext |
url-free |
0 |
issn |
1439-6319 0301-5548 |
coden |
EJAPC |
zdb |
124793-1 |
location_hierarchy_facet |
0/Deutschland/ 1/Deutschland/Berlin/ |
topic |
Kontraktionszeit Leistungsphysiologie Lendenwirbelsäule M. erector spinae Muskelkontraktion Myotonometrie Reliabilität Reproduzierbarkeit Sportmedizin Tensiomyographie Varianzanalyse |
topic_facet |
Kontraktionszeit Leistungsphysiologie Lendenwirbelsäule M. erector spinae Muskelkontraktion Myotonometrie Reliabilität Reproduzierbarkeit Sportmedizin Tensiomyographie Varianzanalyse |
topic_en |
contraction time exercise physiology lumbar spine m. erector spinae muscle contraction myotonometry reliability reproducability sports medicine tensiomyography variance analysis |
topic_en_facet |
contraction time exercise physiology lumbar spine m. erector spinae muscle contraction myotonometry reliability reproducability sports medicine tensiomyography variance analysis |
synonym |
Medizin Geschichte der Medizin Untersuchung, sportmedizinische Wasserdampf Arbeitsphysiologie Physiologie Sportphysiologie Kontraktionsgeschwindigkeit Varianz |
synonym_en |
physiology of exercise performance physiology erector muscle of spine contraction duration duration of contraction |
journal_facet |
European journal of applied physiology |
container_title |
European journal of applied physiology |
container_volume |
118 |
container_issue |
7 |
container_start_page |
S. 1349-1359 |
has_references |
1 |
institution |
BISp |
journal_fac |
JO00000100345 |
journal_year |
2018 |
journal_issue |
7 |
_version_ |
1791509772103581696 |
score |
13,560151 |