Oxygen cost of the CF–DND fire fit test in males and females

Gespeichert in:
Bibliographische Detailangaben
Deutscher übersetzter Titel:Sauerstoffverbrauch von Männern und Frauen beim CF–DND-Feuerwehr-Fitnesstest
Autor:Dreger, Randy W.; Petersen, Stewart R.
Erschienen in:Applied physiology, nutrition, and metabolism
Veröffentlicht:32 (2007), 3, S. 454-462, Lit.
Format: Literatur (SPOLIT)
Publikationstyp: Zeitschriftenartikel
Medienart: Elektronische Ressource (online) Gedruckte Ressource
Sprache:Englisch
ISSN:1715-5312, 1715-5320
DOI:10.1139/H07-020
Schlagworte:
Online Zugang:
Erfassungsnummer:PU201801000449
Quelle:BISp
TY  - JOUR
AU  - Dreger, Randy W.
A2  - Dreger, Randy W.
A2  - Petersen, Stewart R.
DB  - BISp
DP  - BISp
KW  - Feuerwehr
KW  - Fitnesstest
KW  - Frau
KW  - Leistungsphysiologie
KW  - Mann
KW  - Sauerstoffaufnahme
KW  - Sauerstoffversorgung
KW  - Sportmedizin
KW  - Untersuchung, vergleichende
LA  - eng
TI  - Oxygen cost of the CF–DND fire fit test in males and females
TT  - Sauerstoffverbrauch von Männern und Frauen beim CF–DND-Feuerwehr-Fitnesstest
PY  - 2007
N2  - The Department of National Defence employs a work-related test circuit comprising 10 various firefighting tasks (FF test) to assess the fitness of incumbent Canadian Forces firefighters. The main purpose of this study was to document the oxygen cost of the FF test over a wide range of performance times. These data were then used to predict the oxygen cost associated with the 8 min completion standard. Finally, we examined the influence of gender on selected physiological responses during the FF test. Thirty male and 23 female subjects practiced the test 3–5 times and then completed, in random order and on separate days, a maximal-effort trial while breathing with either a self-contained breathing apparatus (SCBA) or a portable metabolic measurement system (MMC). The breath-by-breath gas exchange data from the MMC were collapsed into a single value that represented the average oxygen cost for each participant to complete the work simulation. To calculate the average VO2 associated with the 8 min completion time, separate regression lines for test duration and average VO2 were generated for males and females. Analyses of covariance (ANCOVA) revealed that the regression lines for the male and female groups coincided, therefore all data were collapsed. The resulting regression equation predicted that the average VO2 associated with the 8 min standard was 34.1 (± 4.0) mL•kg–1•min–1, and this value appears consistent with other research on the oxygen cost of firefighting. There was no evidence to suggest that the oxygen cost of meeting the 8 min standard was different for males or females.
L2  - https://dx.doi.org/10.1139/H07-020
DO  - 10.1139/H07-020
SP  - S. 454-462
SN  - 1715-5312
JO  - Applied physiology, nutrition, and metabolism
IS  - 3
VL  - 32
M3  - Elektronische Ressource (online)
M3  - Gedruckte Ressource
ID  - PU201801000449
ER  -