Validity and reliability analysis of Cooper’s 12-minute run and the multistage shuttle run in healthy adults

Gespeichert in:
Bibliographische Detailangaben
Deutscher übersetzter Titel:Validitäts- und Reliabilitätsanalyse des Cooper-12-Minuten-Laufs und des Multistufen-Pendellaufs bei gesunden Erwachsenen
Autor:Penry, Jason T.; Wilcox, Anthony R.; Yun, Joonkoo
Erschienen in:Journal of strength and conditioning research
Veröffentlicht:25 (2011), 3, S. 597-605, Lit.
Format: Literatur (SPOLIT)
Publikationstyp: Zeitschriftenartikel
Medienart: Gedruckte Ressource Elektronische Ressource (online)
Sprache:Englisch
ISSN:1064-8011, 1533-4287
DOI:10.1519/JSC.0b013e3181cc2423
Schlagworte:
Online Zugang:
Erfassungsnummer:PU201105004721
Quelle:BISp

Abstract des Autors

Field tests are a practical method to assess aerobic fitness, but they demonstrate greater error variability than laboratory tests. The principal goals of this study were to identify potential sources of systematic error in 2 commonly used field tests (Cooper’s 12-minute run [12MR] and the multistage shuttle run [MSR]) and estimate the reliability of the 2 tests from these data. In addition, criterion-related validity evidence for field tests was evaluated via Bland-Altman plots. To assess trends across test protocol and test trials, 60 subjects (mean age = 21.8 ± 3.6 years) completed 6 test trials, including 3 trials of each field test. Of these 60 individuals, 21 volunteers completed an incremental treadmill run and expired gas analysis (TR) that was used to establish criterion-related validity evidence for the 2 field tests. G-study analysis of the field test data returned a high reliability coefficient (ϕ = 0.96), with the largest amount of systematic error variance (4.3%) attributable to an interaction between subjects and test occasions. The MSR predicted V̇O2max scores lower than those measured in the laboratory setting (p < 0.01), whereas 12MR and TR scores were not different (p > 0.05). However, Bland-Altman plots showed the 12MR to underestimate V̇O2max scores at lower V̇O2max values and overestimate V̇O2max scores at higher values, a trend not observed in the MSR data. These data suggest high overall reliability for V̇O2max field tests in young, healthy individuals. Nevertheless, test administrators must use caution when attempting to use field test data to predict criterion V̇O2max scores. The MSR appears to be a more useful tool than the 12MR because of a consistent mean bias across fitness levels. Verf.-Referat