Test-retest reliability of sudden ankle inversion measurements in subjects with healthy ankle joints

Gespeichert in:
Bibliographische Detailangaben
Deutscher übersetzter Titel:Test-Retest-Reliabilität von Messungen plötzlicher Sprunggelenkinversionen bei Personen mit gesunden Sprunggelenken
Autor:Eechaute, Christophe ; Vaes, Peter ; Duquet, William; Gheluwe, Bart van
Erschienen in:Journal of athletic training
Veröffentlicht:42 (2007), 1, S. 60-65, Lit.
Format: Literatur (SPOLIT)
Publikationstyp: Zeitschriftenartikel
Medienart: Elektronische Ressource (online) Gedruckte Ressource
Sprache:Englisch
ISSN:1062-6050, 0160-8320, 1938-162X
Schlagworte:
Online Zugang:
Erfassungsnummer:PU201011008118
Quelle:BISp

Abstract

Context: Sudden ankle inversion tests have been used to investigate whether the onset of peroneal muscle activity is delayed in patients with chronically unstable ankle joints. Before interpreting test results of latency times in patients with chronic ankle instability and healthy subjects, the reliability of these measures must be first demonstrated. Objective: To investigate the test-retest reliability of variables measured during a sudden ankle inversion movement in standing subjects with healthy ankle joints. Design: Validation study. Setting: Research laboratory. Patients or Other Participants: 15 subjects with healthy ankle joints (30 ankles). Intervention(s): Subjects stood on an ankle inversion platform with both feet tightly fixed to independently moveable trapdoors. An unexpected sudden ankle inversion of 50° was imposed. Main Outcome Measure(s): We measured latency and motor response times and electromechanical delay of the peroneus longus muscle, along with the time and angular position of the first and second decelerating moments, the mean and maximum inversion speed, and the total inversion time. Correlation coefficients and standard error of measurements were calculated. Results: Intraclass correlation coefficients ranged from 0.17 for the electromechanical delay of the peroneus longus muscle (standard error of measurement = 2.7 milliseconds) to 0.89 for the maximum inversion speed (standard error of measurement = 34.8 milliseconds). Conclusions: The reliability of the latency and motor response times of the peroneus longus muscle, the time of the first and second decelerating moments, and the mean and maximum inversion speed was acceptable in subjects with healthy ankle joints and supports the investigation of the reliability of these measures in subjects with chronic ankle instability. The lower reliability of the electromechanical delay of the peroneus longus muscle and the angular positions of both decelerating moments calls the use of these variables into question. Verf.-Referat