Parametrisierung posturaler Subsysteme mit Posturografie

Gespeichert in:
Bibliographische Detailangaben
Englischer übersetzter Titel:Parametrisation of postural systems with posturography
Autor:Schwesig, René; Lauenroth, A.; Müller, A.; Becker, S.; Hottenrott, Kuno
Erschienen in:Manuelle Medizin
Veröffentlicht:44 (2006), 5, S. 376-384, Lit.
Format: Literatur (SPOLIT)
Publikationstyp: Zeitschriftenartikel
Medienart: Gedruckte Ressource
Sprache:Deutsch
ISSN:0025-2514, 1433-0466
Schlagworte:
Online Zugang:
Erfassungsnummer:PU200909004429
Quelle:BISp
id PU200909004429
bisp-collection db
format Literatur
last_indexed 2011-05-16T07:54:55Z
first_indexed 2009-09-09T12:25:40Z
publication_source BISp
subformat Zeitschriftenartikel
hierarchy_top_id JO00000100396
hierarchy_parent_id JOI200600050100396
hierarchy_top_title Manuelle Medizin
hierarchy_parent_title Manuelle Medizin, 2006, 5
is_hierarchy_id PU200909004429
is_hierarchy_title Parametrisierung posturaler Subsysteme mit Posturografie
hierarchy_sequence 0376
recordtype bisparticle
publishDate 2006
publishDate_facet 2006
language deu
title Parametrisierung posturaler Subsysteme mit Posturografie
spellingShingle Parametrisierung posturaler Subsysteme mit Posturografie
Balance
Gleichgewichtsvermögen
Haltungsstabilität
Kraftmessplatte
Körperhaltung
Körperschwerpunkt
Körperwahrnehmung
Regulation
Schwingung
Vestibularapparat
title_sort parametrisierung posturaler subsysteme mit posturografie
title_short Parametrisierung posturaler Subsysteme mit Posturografie
title_alt Parametrisation of postural systems with posturography
title_alt_lang eng
media_type Gedruckte Ressource
city Heidelberg
abstract Hintergrund: Die Messung und Objektivierung der Haltungsregulation ist sehr aufwändig und schwierig, da es sich beim posturalen System um ein komplexes, multimodal beeinflusstes und multilokuläres System handelt. Bislang lassen sich Aussagen zu etwaigen Interventionseffekten in der Regel nur auf der Produktebene, jedoch nicht auf der Prozessebene treffen. Fragestellung: Ziel dieser Untersuchung war es, ein neues posturografisches Messsystem, das Interaktive Balancesystem (IBS), auf seine interne Validität hinsichtlich der Parametrisierung der posturalen Subsysteme mithilfe der Fourier-Analyse zu prüfen. Patienten und Methodik: Anhand von drei Fall-Kontroll-Studien (F 1: Sehbehinderte, F 2–4: Cochlear-Implant-Patienten, F 7–8: Kleinhirn- und Parkinson-Patienten) und einer Gruppe mit artifiziell induzierter Störung der Somatosensorik (F 5–6: Kälteapplikation) wurde die frequenzanalytische (FFT) Repräsentation der einzelnen posturalen Subsysteme (F 1: visuell, F 2–4: peripher-vestibulär, F 5–6: somatosensorisch; F 7–8: zentral, zerebellär-nigrostriatal) quasiexperimentell mit dem IBS überprüft. Ergebnisse und Diskussion Auf der Basis der Frequenzbereiche (0,03–3,0 Hz) der Fourier-Analyse scheint es möglich zu sein, valide und reliable Rückschlüsse bezüglich der posturalen Subsysteme zu ziehen. Veränderungen im Bereich des somatosensorischen Systems können ebenfalls an einem Frequenzbereich (F 5–6) festgemacht werden. Eine Störung im somatosensorischen System tangiert zwar die Frequenzbereiche F 1 und F 7–8 signifikant, was aufgrund der Komplexität dieses Systems auch nicht überrascht. Jedoch waren signifikante Veränderungen im Frequenzbereich F 5–6 nur bei expliziter somatosensorischer Einflussnahme zu beobachten. Schlussfolgerung: Die Zuordnung der Frequenzbereiche der Fourier-Analyse zu den posturalen Subsystemen stellt einen Schritt zur Quantifizierung und Parametrisierung sensomotorischer Interventionseffekte dar. Sie sollte jedoch keinesfalls als endgültig betrachtet werden. Unter Umständen sind einzelne Frequenzbereiche auch als Indikatoren für mehrere Systeme in Betracht zu ziehen, was in weiteren Untersuchungen abzuklären ist. Verf.-Referat
Introduction Measurement and objectivisation of postural regulation is very demanding and difficult, because the postural system is a complex, multimodally influenced and multilocated system. Until now response to possible interventional effects could only be determined on a product basis, but not on a process-oriented basis. Hypothesis: The goal of this study was to evaluate a new posturographic measurement system (interactive balance system, IBS) regarding internal validity towards the parametrisation of postural subsystems using Fourier analysis. Patients and methods Three case control studies (F1: visually impaired group, F2–4: cochlear implant group, F7–8: cerebellar lesions, Parkinson group) and a group with artificially induced somatosensory lesion (F5–6: cold application) were used to evaluate the frequency analytic (FFT) representation of different postural subsystems (F1: visual, F2–4: peripheral vestibular, F5–6: somatosensory, F7–8: central, cerebellar-nigrostriatal) with IBS. Results and discussion: The Fourier analysis with a frequency range of 0.03–3.0 Hz allows a valid and reliable evaluation of postural subsystems. Changes of the somatosensory system can also be detected in a specific frequency range (F 5–6). A lesion of the somatosensory system also affects frequency parameters F1 and F7–8, which can be expected due to the complexity of the system. Significant changes however were only observed with special somatosensory triggering. Conclusion: The correlation of frequency parameters of the Fourier analysis to postural subsystems represents a step towards quantification and parametrisation of somatosensory interventional effects. However, it is far from being totally conclusive; under certain conditions single frequency ranges may act as indicators of different systems, which has to be investigated in further studies. Verf.-Referat
abstract_lang deu
eng
abstract_type author
abstract
author2 Schwesig, René
Lauenroth, A.
Müller, A.
Becker, S.
Hottenrott, Kuno
author_facet Schwesig, René
Lauenroth, A.
Müller, A.
Becker, S.
Hottenrott, Kuno
author2-role Autor
Autor
Autor
Autor
Autor
author2-authorityid P132075



P1833
author_author_facet Schwesig, René
Lauenroth, A.
Müller, A.
Becker, S.
Hottenrott, Kuno
author2-synonym




author2_hierarchy_facet 0/Autor/
1/Autor/Schwesig, René/
0/Autor/
1/Autor/Lauenroth, A./
0/Autor/
1/Autor/Müller, A./
0/Autor/
1/Autor/Becker, S./
0/Autor/
1/Autor/Hottenrott, Kuno/
issn 0025-2514
1433-0466
spelling 0025-2514
1433-0466
MLMZB
206690-7
Balance
Gleichgewichtsvermögen
Haltungsstabilität
Kraftmessplatte
Körperhaltung
Körperschwerpunkt
Körperwahrnehmung
Regulation
Schwingung
Vestibularapparat
balance
balance
body perception
body posture
center of gravity
force platform
postural stability
regulation
vestibular apparatus
vibration
Körperstellung
Position
Stellung
Haltungsänderung
Haltung
Informationswahrnehmung
Gleichgewicht
Schwerpunktzentrum
Schwerpunktbestimmung
Kraftplattform
Gleichgewichtsorgan
perception of one's body
center of mass
oscillation
force plate
Parametrisierung posturaler Subsysteme mit Posturografie
PU200909004429
200909004429
coden MLMZB
zdb 206690-7
location_hierarchy_facet 0/Deutschland/
1/Deutschland/Baden-Württemberg/
topic Balance
Gleichgewichtsvermögen
Haltungsstabilität
Kraftmessplatte
Körperhaltung
Körperschwerpunkt
Körperwahrnehmung
Regulation
Schwingung
Vestibularapparat
topic_facet Balance
Gleichgewichtsvermögen
Haltungsstabilität
Kraftmessplatte
Körperhaltung
Körperschwerpunkt
Körperwahrnehmung
Regulation
Schwingung
Vestibularapparat
topic_en balance
balance
body perception
body posture
center of gravity
force platform
postural stability
regulation
vestibular apparatus
vibration
topic_en_facet balance
balance
body perception
body posture
center of gravity
force platform
postural stability
regulation
vestibular apparatus
vibration
synonym Körperstellung
Position
Stellung
Haltungsänderung
Haltung
Informationswahrnehmung
Gleichgewicht
Schwerpunktzentrum
Schwerpunktbestimmung
Kraftplattform
Gleichgewichtsorgan
synonym_en perception of one's body
center of mass
oscillation
force plate
journal_facet Manuelle Medizin
container_title Manuelle Medizin
container_volume 44
container_issue 5
container_start_page S. 376-384
has_references 1
institution BISp
journal_fac JO00000100396
journal_year 2006
journal_issue 5
_version_ 1791514758126501888
score 13,558404