Three-dimensional pushrim forces during two speeds of wheelchair propulsion

Gespeichert in:
Bibliographische Detailangaben
Deutscher übersetzter Titel:Dreidimensionale Kraefte am Handgreifring bei zwei Geschwindigkeiten des Rollstuhlfahrens
Autor:Boninger, M.L.; Cooper, R.A.; Robertson, R.N.; Shimada, S.D.
Erschienen in:American journal of physical medicine & rehabilitation
Veröffentlicht:76 (1997), 5, S. 420-426, Lit.
Format: Literatur (SPOLIT)
Publikationstyp: Zeitschriftenartikel
Medienart: Gedruckte Ressource
Sprache:Englisch
ISSN:0894-9115, 0002-9491, 1537-7385
Schlagworte:
Online Zugang:
Erfassungsnummer:PU199805302031
Quelle:BISp

Abstract

Upper limb pain frequently occurs in manual wheelchair users. Analyzing the pushrim forces and hub moments occurring during wheelchair propulsion is a first step in gaining insight into the cause of this pain. The objectives of this study were as follows: to describe the forces and moments occurring during wheelchair propulsion; to obtain variables that characterize pushrim forces and are statistically stable; and to determine how these variables change with speed. Convenience samples (n=6) of paralympic athletes who use manual wheelchairs for mobility and have unimpaired arm function were tested. Each subject propelled a standard wheelchair on a dynamometer at 1.3 and 2.2 m/s. Biomechanical data were obtained using a force- and moment-sensing pushrim and a motion analysis system. A number of variables that describe the force and moment curves were evaluated for stability using Cronbach's alpha. Those measures found to be stable at each speed were then examined for differences associated with speed. The tangential, radial, and medial-lateral forces were found to comprise approximately 55, 35, and 10% of the resultant force, respectively. In addition to duration of stroke and propulsion, the following variables were found to be stable and to differ with speed (1.3 m/s+/-SD; 2.2 m/s+/-SD): peak force tangential to the pushrim (45.9+/-17.9 N; 62.1+/-30 N), peak moment radial to the hub (9.8+/-4.5 N/m 13.3+/-6 N/m), maximum rate of rise of the tangential force (911.7+/-631.7 N/sec; 1262.3+/-570.7 N/sec), and maximum rate of rise of the moment about the hub (161.9+/-78.3 N/m/s; 255.2+/-115.4 N/m/s). This study found stable parameters that characterize pushrim forces during wheelchair propulsion and varied with speed. Almost 50% of the forces exerted at the pushrim are not directed toward motion and, therefore, either apply friction to the pushrim or are wasted. Ultimately, this type of investigation may provide insight into the cause and prevention of upper limb injuries in manual wheelchair users. Verf.-Referat