The effect of Tai Chi training on cardiorespiratory fitness in healthy adults: a systematic review and meta-analysis.

Autor: Guohua Zheng; Shuzhen Li; Maomao Huang; Feiwen Liu; Jing Tao; Lidian Chen
Sprache: Englisch
Veröffentlicht: 2015
Quelle: Directory of Open Access Journals: DOAJ Articles
Online Zugang: http://europepmc.org/articles/PMC4332633?pdf=render
https://doaj.org/toc/1932-6203
1932-6203
doi:10.1371/journal.pone.0117360
https://doaj.org/article/4fa5323fcc294d489826d78759394a25
https://doi.org/10.1371/journal.pone.0117360
https://doaj.org/article/4fa5323fcc294d489826d78759394a25
Erfassungsnummer: ftdoajarticles:oai:doaj.org/article:4fa5323fcc294d489826d78759394a25

Zusammenfassung

BACKGROUND:Tai Chi may be efficient for healthy adults to improve the cardiorespiratory fitness, but there is no systematic evaluation for its effectiveness. OBJECTIVE:To systematically assess the effectiveness of Tai Chi on cardiorespiratory fitness in healthy adults. METHODS:Seven electronic databases were searched from their inception to October 2013. The controlled trails including randomized controlled trial (RCT), non-randomized controlled trial (NRCT), self-controlled trial (SCT), and cohort study (CS) testing Tai Chi exercise against non-intervention control conditions in healthy adults that assessed any type cardiorespiratory fitness outcome measures were considered. Two reviewers independently performed the selection of the studies according to predefined criteria. The risk of bias was assessed using Cochrane criteria. RevMan 5.2 software was applied for data analysis. RESULTS:Twenty studies (2 RCTs, 8 NRCTs, 3 SCTs, and 7 CSs) with 1868 participants were included, but most of them belonged to low methodological quality. The results of systematic review showed that Tai Chi exercise had positive effect on majority outcomes of cardio function (Blood pressure: n = 536, SPB SMD = -0.93, 95% CI -1.30 to -0.56, P < 0.00001; DBP SMD = -0.54, 95% CI -0.90 to -0.18, P < 0.00001; heart rate at quiet condition: n = 986, SMD = -0.72, 95% CI -1.27 to -0.18, P = 0.010; stroke volume: n = 583, SMD = 0.44, 95% CI 0.28 to 0.61, P < 0.00001; cardio output: n = 583, MD = 0.32 L/min, 95% CI 0.08 to 0.56, P = 0.009), lung capacity (FVC at quiet condition: n = 1272, MD = 359.16 mL, 95% CI 19.57 to 698.75, P = 0.04 for less than one year intervention, and MD = 442.46 mL, 95% CI 271.24 to 613.68, P<0.0001 for more than one year intervention; V·O2peak: n = 246, SMD = 1.33, 95% CI 0.97 to 1.70, P < 0.00001), and cardiorespiratory endurance (O2 pulse at quiet condition: n = 146, SMD = 1.04; 95% CI 0.69 to 1.39; P < 0.00001; stair test index at quiet condition: n = 679, SMD = 1.34, 95% CI 0.27 to 2.40, p = ...