Estimation of energy expenditure using accelerometers and activity-based energy models : validation of a new device

Gespeichert in:
Bibliographische Detailangaben
Deutscher übersetzter Titel:Bestimmung des Kalorienverbrauchs anhand eines Beschleunigungssensors und aktivitätsbasierender Energiemodelle : Validierung eines neuen Gerätes
Autor:Härtel, Sascha; Gnam, Jens-Peter; Löffler, Simone; Bös, Klaus
Erschienen in:European review of aging and physical activity
Veröffentlicht:8 (2011), 2 (Socioeconomic perspective on physical activity and aging), S. 109-114, Lit.
Format: Literatur (SPOLIT)
Publikationstyp: Zeitschriftenartikel
Medienart: Gedruckte Ressource Elektronische Ressource (online)
Sprache:Englisch
ISSN:1813-7253, 1861-6909
DOI:10.1007/s11556-010-0074-5
Schlagworte:
Online Zugang:
Erfassungsnummer:PU201211007592
Quelle:BISp

Abstract des Autors

Over the last few years, the estimation of energy expenditure with accelerometers has become more and more accurate due to improvements in sensor technology. Significant enhancement could be reached by model-based estimation regarding different activity types. The kmsMove-sensor (movisens GmbH, Karlsruhe, Germany) is a device that is used to compute human energy expenditure using motion-dependent calculation models. It is outfitted with an accelerometer to measure body acceleration during certain movements and activities. To validate its accuracy, the sensor was compared to indirect calorimetry as criterion measure. For this experiment, nine subjects (all males, age 46.4 ± 10.9 years, 28–64 years) were equipped with the kmsMove-sensor as well as a portable indirect calorimeter and their energy consumption was measured over a time period of 100 min. Additionally, the energy consumption of seven out of the above-mentioned nine subjects was measured over an average of 7 h. The measurements took place in a rehabilitation clinic, where the subjects completed their regular daily rehabilitation activities. An analysis of the data revealed ICCs between the kmsMove-sensor and indirect calorimetry for the time period of 100 min of 0.82 (0.38–0.96; p = 0.003) and for an averaged measuring time of 7 h of 0.81 (0.22–0.97; p = 0.01). Furthermore, a Bland–Altman analysis for the time period of 100 min led to a difference of the means of 4.3 kcal (limits of agreement: −94.3 and 102.9 kcal) and for the time period of an average of 7 h to −14.0 kcal (limits of agreement: −320.0 and 292.0 kcal). These findings indicate that the kmsMove-sensor is an appropriate measuring device with relatively good accuracy to assess human energy expenditure in rehabilitation patients. However, this study has some limiting aspects (small sample size, artificial setting) which could influence validity. Verf.-Referat