Test-retest reliability of isokinetic hip adductor and flexor muscle strength

Saved in:
Bibliographic Details
Title translated into German:Test-Retest-Reliabilitaet der isokinetischen Kraft der Hueftgelenkadduktoren und -beuger
Author:Emery, C.A.; Maitland, M.E.; Meeuwisse, W.H.
Published in:Clinical journal of sport medicine
Published:9 (1999), 2 , S. 79-85, Lit.
Format: Publications (Database SPOLIT)
Publication Type: Journal article
Media type: Print resource
Language:English
ISSN:1050-642X
Keywords:
Online Access:
Identification number:PU199908400930
Source:BISp

Author's abstract

Objective: To determine the test-retest reliability of eccentric hip flexor and adductor peak torque and endurance using a Cybex Norm isokinetic dynamometer and to evaluate muscle soreness after exercise as a result of the testing procedure. Design: Prospective test-retest reliability study. Participants: A total of 19 male volunteers (21-43 years old). Intervention: Tests included hip flexor and adductor peak torque strength measured at 60% (concentric and eccentric) and endurance measurements (total work done over 20 continuous concentric/eccentric contractions at 150ø/s). Subjects were tested on three occasions at 1-week intervals. Main outcome measures: Repeated measures analysis of variance was performed for all dependent variables including the subject's dominant and nondominant side among the three test sessions. Intraclass correlation coefficients (ICCs) were calculated to compare the data between sessions. In addition, simple linear regression analysis was completed to determine the relationship between session measurements for all measures with ICC>0.75. Results: The main findings of this study are that eccentric peak hip adductor torque was reliably measured on a Cybex Norm isokinetic dynamometer using a continuous eccentric/concentric cycle protocol at a speed of 60ø/s (ICC>0.84). Peak concentric adductor torque and peak eccentric and concentric hip flexor torque were less reliable using the same protocol (ICC<0.67). Endurance measurements, using total work done over 20 repetitions, were not reliable for hip flexor and adductor muscle groups using a continuous eccentric/concentric cycle protocol at a speed of 150ø/s (ICC<0.55). Posttest muscle soreness was found to be of significant concern with such a protocol. Conclusion: The results from this test-retest reliability study confirm the reliability of eccentric peak hip adductor torque measurements for use clinically and in future research. In addition, the need to assess posttest muscle soreness after isokinetic muscle testing is confirmed. Verf.-Referat