In vivo determination of the patella tendon and hamstrings moment arms in adult males using videofluoroscopy during submaximal knee extension and flexion

Gespeichert in:
Bibliographische Detailangaben
Deutscher übersetzter Titel:In-vivo-Messung der Kraftmomentarme der Patellarsehne und der Hamstrings waehrend submaximaler Kniestreck- und -beugeuebungen bei erwachsenen Maennern mit Hilfe der Videofluoroskopie
Autor:Kellis, E.; Baltzopoulos, V.
Erschienen in:Clinical biomechanics
Veröffentlicht:14 (1999), 2, S. 118-124, Lit.
Format: Literatur (SPOLIT)
Publikationstyp: Zeitschriftenartikel
Medienart: Gedruckte Ressource Elektronische Ressource (online)
Sprache:Englisch
ISSN:0268-0033, 1879-1271
DOI:10.1016/S0268-0033(98)00055-2
Schlagworte:
Online Zugang:
Erfassungsnummer:PU199903308359
Quelle:BISp

Abstract des Autors

Objective: The determination of patella tendon and hamstrings moment arms. Design: The moment-arms were determined using a videofluoroscopy imaging method. Background: The determination of hamstrings and quadriceps moment arms is important for the examination of muscle and joint forces in biomechanical applications. Methods: Ten males performed one knee extension-flexion movement at a very slow (non-constant) angular velocity in front of the image intensifier screen of a videofluoroscopic system. The image of a calibration phantom with 2 cm squares was also recorded. Thirty five calibration points with known coordinates were digitized for the establishment of the polynomial equations that determined the coordinates of any point in the calibration phantom from its corresponding video coordinates. Fourteen control points were digitized and the difference between the actual and predicted coordinates was measured. The patella tendon and hamstrings (biceps femoris) moment arms to the tibiofemoral contract point were calculated. Results: The mean error in the digitizing of the control points using the image deformation method ranged from 0.182 mm to 0.267 mm. The mean patella tendon moment arm ranged from 36.91(SD 3.2) mm to 42.63(SD 4.5) mm. The hamstrings moment arm ranged from 23.93(SD 2.59) to 28.25(SD 3.04) mm. Conclusion: The patellar tendon and hamstring moment-arms were determined using a videofluoroscopy method with acceptable accuracy. These parameters can be used for the biomechanical analysis of knee joint movements in two dimensional applications. Relevance: The determination of the patella tendon and hamstrings moment arms in vivo is essential for the examination of joint and muscle forces around the knee during dynamic activities. Verf.-Referat