Estimation of cardiorespiratory endurance in young adult men using 12-min submaximal treadmill walk/run test
Gespeichert in:
Deutscher übersetzter Titel: | Bestimmung der kardiopulmonalen Ausdauer junger Maenner aus einem 12 Minuten dauernden submaximalen Gehen/Laufen-Test auf dem Laufband |
---|---|
Autor: | Kumagai, M.; Nakagaichi, M.; Nishijima, T.; Tanaka, K. |
Erschienen in: | Japanese journal of physical fitness and sports medicine |
Veröffentlicht: | 46 (1997), 2, S. 179-188, Lit. |
Format: | Literatur (SPOLIT) |
Publikationstyp: | Zeitschriftenartikel |
Medienart: | Gedruckte Ressource |
Sprache: | Japanisch |
ISSN: | 0039-906X, 1881-4751 |
Schlagworte: | |
Online Zugang: | |
Erfassungsnummer: | PU199710207673 |
Quelle: | BISp |
id |
PU199710207673 |
---|---|
bisp-collection |
db |
format |
Literatur |
last_indexed |
2009-04-27T15:32:46Z |
first_indexed |
2001-07-24T13:37:19Z |
publication_source |
BISp |
subformat |
Zeitschriftenartikel |
hierarchy_top_id |
JO00000000690 |
hierarchy_parent_id |
JOI199700020000690 |
hierarchy_top_title |
Japanese journal of physical fitness and sports medicine |
hierarchy_parent_title |
Japanese journal of physical fitness and sports medicine, 1997, 2 |
is_hierarchy_id |
PU199710207673 |
is_hierarchy_title |
Estimation of cardiorespiratory endurance in young adult men using 12-min submaximal treadmill walk/run test |
hierarchy_sequence |
0179 |
recordtype |
bisparticle |
publishDate |
1997 |
publishDate_facet |
1997 |
language |
jpn |
title |
Estimation of cardiorespiratory endurance in young adult men using 12-min submaximal treadmill walk/run test |
spellingShingle |
Estimation of cardiorespiratory endurance in young adult men using 12-min submaximal treadmill walk/run test Ausdauertest Belastung, submaximale Belastungswahrnehmung Berechnung Gehen Kapazität, aerobe Laufbandergometrie Laufen Leistungsdiagnostik Sportmedizin |
title_sort |
estimation of cardiorespiratory endurance in young adult men using 12min submaximal treadmill walk/run test |
title_short |
Estimation of cardiorespiratory endurance in young adult men using 12-min submaximal treadmill walk/run test |
title_alt |
Bestimmung der kardiopulmonalen Ausdauer junger Maenner aus einem 12 Minuten dauernden submaximalen Gehen/Laufen-Test auf dem Laufband |
title_alt_lang |
deu |
media_type |
Gedruckte Ressource |
city |
Tokio |
abstract |
The purpose of this study was to clarify the validity of 12-min submaximal treadmill walk (TMW) and run (TMR) tests, as indirect measures of cardiorespiratory endurance, and to develop estimation equations of cardiorespiratory endurance using TMW or TMR performance and some other useful items correlating with cardiorespiratory endurance. Fifty-one young adult men, aged 20 to 34 years (22.8+/-3.6), walked or ran for 12 minutes on the treadmill at the intensity corresponding to the level 13 on the Borg's ratings of perceived exertion (RPE 13), and performed a maximal incremental exercise test. Mean (+/-SD) of oxygen uptake corresponding to anaerobic threshold (VO2AT) and maximal oxygen uptake (VO2max) were 42.0+/-9.0 ml/kg/min and 55.9+/-7.4 ml/kg/min, respectively, and mean (+/-SD) of 12-min walk and run distances were 1221+/-103 m and 2108+/-269 m, respectively. Cardiorespiratory endurance indices (VO2AT and VO2max) significantly correlated with TMW (r=0.49 and 0.48, respectively) and with TMR (r=0.69 and 0.68, respectively). A stepwise multiple regression analysis was applied to determine the estimation equations of the cardiorespiratory endurance using VO2AT or VO2max as a dependent variable, and TMW or TMR distance, age, resting heart rate (HRrest), and exercise frequency in a week as independent variables. The multiple regression equations of VO2AT and VO2max were developed as follows: When TMW distance entered as an independent variable, VO2AT = 20.781 X1 + 2.298 X3 - 0.297 X4 + 31.855 (r=0.83, SEE=5.33 ml/kg/min); VO2max = 19.941 X1 + 1.127 X3 - 0.208 X4 - 0.656 X5 - 0.853 X6 + 77.884 (r=0.88, SEE=3.96 ml/kg/min), and when TMR distance entered as an independent variable, VO2AT = 15.443 X2 + 2.158 X3 - 0.157 X4 + 14.234 (r=0.90, SEE=4.18 ml/kg/min); VO2max = 10.817 X2 + 1.274 X3 - 0.1946 X4 - 0.504 X5 + 55.234 (r=0.89, SEE=3.79 ml/kg/min), where X1: TMW distance (m), X2: TMR distance (m), X3: exercise frequency in a week (d/wk), X4: HRrest (b/min), X5: age (yr) and X6: BMI. It is concluded that cardiorespiratory endurance could be better estimated by a combination of submaximal exercise performance and some easily measurable items correlating with cardiorespiratory endurance such as exercise frequency, circulatory function, chronological age and body composition. Verf.-Referat |
abstract_lang |
eng |
abstract_type |
author |
author2 |
Kumagai, M. Nakagaichi, M. Nishijima, T. Tanaka, K. |
author_facet |
Kumagai, M. Nakagaichi, M. Nishijima, T. Tanaka, K. |
author2-role |
Autor Autor Autor Autor |
author2-authorityid |
|
author_author_facet |
Kumagai, M. Nakagaichi, M. Nishijima, T. Tanaka, K. |
author2-synonym |
|
author2_hierarchy_facet |
0/Autor/ 1/Autor/Kumagai, M./ 0/Autor/ 1/Autor/Nakagaichi, M./ 0/Autor/ 1/Autor/Nishijima, T./ 0/Autor/ 1/Autor/Tanaka, K./ |
issn |
0039-906X 1881-4751 |
spelling |
0039-906X 1881-4751 TAKAA 600775-2 Ausdauertest Belastung, submaximale Belastungswahrnehmung Berechnung Gehen Kapazität, aerobe Laufbandergometrie Laufen Leistungsdiagnostik Sportmedizin aerobic capacity calculation endurance test perceived exertion performance diagnostics race walking running sports medicine submaximal load treadmill ergometry Belastung Muskelarbeit, submaximale Geher Lauf Laufhaltung Laufsport Kapazität Leistungsfähigkeit, aerobe Anstrengung Anstrengungsempfinden Anstrengungsgrad Informationswahrnehmung Leistungsempfinden Borg-Skala Diagnostik Leistungsbestimmung Leistungsdiagnose Leistungserfassung Leistungsfeststellung Trainingsdiagnostik Medizin Geschichte der Medizin Untersuchung, sportmedizinische Wasserdampf submaximal workload submaximal exercise submaximal work walking computation Estimation of cardiorespiratory endurance in young adult men using 12-min submaximal treadmill walk/run test PU199710207673 199710207673 |
coden |
TAKAA |
zdb |
600775-2 |
location_hierarchy_facet |
0/Japan/ |
topic |
Ausdauertest Belastung, submaximale Belastungswahrnehmung Berechnung Gehen Kapazität, aerobe Laufbandergometrie Laufen Leistungsdiagnostik Sportmedizin |
topic_facet |
Ausdauertest Belastung, submaximale Belastungswahrnehmung Berechnung Gehen Kapazität, aerobe Laufbandergometrie Laufen Leistungsdiagnostik Sportmedizin |
topic_en |
aerobic capacity calculation endurance test perceived exertion performance diagnostics race walking running sports medicine submaximal load treadmill ergometry |
topic_en_facet |
aerobic capacity calculation endurance test perceived exertion performance diagnostics race walking running sports medicine submaximal load treadmill ergometry |
synonym |
Belastung Muskelarbeit, submaximale Geher Lauf Laufhaltung Laufsport Kapazität Leistungsfähigkeit, aerobe Anstrengung Anstrengungsempfinden Anstrengungsgrad Informationswahrnehmung Leistungsempfinden Borg-Skala Diagnostik Leistungsbestimmung Leistungsdiagnose Leistungserfassung Leistungsfeststellung Trainingsdiagnostik Medizin Geschichte der Medizin Untersuchung, sportmedizinische Wasserdampf |
synonym_en |
submaximal workload submaximal exercise submaximal work walking computation |
journal_facet |
Japanese journal of physical fitness and sports medicine |
container_title |
Japanese journal of physical fitness and sports medicine |
container_volume |
46 |
container_issue |
2 |
container_start_page |
S. 179-188 |
has_references |
1 |
institution |
BISp |
journal_fac |
JO00000000690 |
journal_year |
1997 |
journal_issue |
2 |
_version_ |
1791517069757382656 |
score |
13,546046 |