Carbon monoxide and nitrogen dioxide exposures in indoor ice skating rinks

Gespeichert in:
Bibliographische Detailangaben
Deutscher übersetzter Titel:Kohlenmonoxid- und Stickstoffdioxidbelastung in Eislaufhallen
Autor:Lee, Kiyoung; Yanagisawa, Yukio; Spengler, John D.; Nakai, Satoshi
Erschienen in:Journal of sports sciences
Veröffentlicht:12 (1994), 3, S. 279-283, Lit.
Format: Literatur (SPOLIT)
Publikationstyp: Zeitschriftenartikel
Medienart: Gedruckte Ressource
Sprache:Englisch
ISSN:0264-0414, 1466-447X
Schlagworte:
Online Zugang:
Erfassungsnummer:PU199408072837
Quelle:BISp

Abstract des Autors

Exposures to cabon monoxide (CO) and nitrogen dioxide (NO2) were determined in seven enclosed ice skating rinks and an outdoor rink. The uptake of CO was also determined by the difference in alveolar CO concentration of the non-smoking hockey players before and after games. Carbon monoxide concentrations in enclosed rinks ranged from 4 to 117 ppm and NO2 concentrations from 342 to 2729 ppb for 2 h hockey games. The CO uptakes were linearly related to the ambientCO concentrations. Alveolar CO of the hockey players increased on average by 0.53 ppm per 1 ppm CO exposure over 2 h. Considering the CO and NO2 levels currently measured in enclosed ice skating rinks, indoor air quality guidelines or standards should be established. It is recommended that 1 h maximum allowable limits of 20 ppm CO and 250 ppb NO2 be established. Verf.-Referat