A comparative study of blood lactate tests in swimming
Gespeichert in:
Deutscher übersetzter Titel: | Eine vergleichende Untersuchung der Blutlaktat-Tests im Schwimmsport |
---|---|
Autor: | Keskinen, K.L.; Komi, P.V.; Rusko, H. |
Erschienen in: | International journal of sports medicine |
Veröffentlicht: | 10 (1989), 3, S. 197-201, Lit. |
Format: | Literatur (SPOLIT) |
Publikationstyp: | Zeitschriftenartikel |
Medienart: | Gedruckte Ressource Elektronische Ressource (online) |
Sprache: | Englisch |
ISSN: | 0172-4622, 1439-3964 |
DOI: | 10.1055/s-2007-1024900 |
Schlagworte: | |
Online Zugang: | |
Erfassungsnummer: | PU199205052803 |
Quelle: | BISp |
TY - JOUR AU - Keskinen, K.L. A2 - Keskinen, K.L. A2 - Komi, P.V. A2 - Rusko, H. DB - BISp DP - BISp KW - Belastung, aerobe KW - Belastung, anaerobe KW - Blutlaktat KW - Herzfrequenz KW - Laktatbestimmung KW - Leistungsdiagnostik KW - Schwimmgeschwindigkeit KW - Schwimmsport KW - Schwimmstrecke KW - Sportmedizin LA - eng TI - A comparative study of blood lactate tests in swimming TT - Eine vergleichende Untersuchung der Blutlaktat-Tests im Schwimmsport PY - 1989 N2 - Three different modes of lactate tests were studied. Eleven male competitive swimmers performed the tests (n x 100 m, n x 300 m, 2 x 100 m + 2 x 400 m) within 5 days. Swimming velocity (V) vs blood lactase (BLa) and V vs heart rate (HR) curves were averaged. In V vs BLa comparisons, the BLa values of 4 mmol/l in 2 x 400 m, 3 mmol/l in n x 300 m, and 2 mmol/l in n x 100 m modes were found to correspond to the same V. Although the resting BLa values were similar before the testing occasions, the initial BLa value in very easy swimming was lower in the n x 300 m than in the n x 100 m mode. The elimination of lactate most probably caused this difference. The highest BLa value was measured in the n x 100 m (14.9 mmol/l) and 2 x 100 m (13.6 mmol/l) exercise modes demonstrating a higher rate of anaerobic energy production than in the n x 300 m or 2 x 400 m test modes. In HR vs V comparison, the n x 300 m and 2 x 400 m modes demonstrated similar HR values in relation to V. To measure the whole intensity area, a combination of tests should be applied by performing an incremental set with several steady-state loadings (aerobic) and one or two 100 m swims (anaerobic) in one test session. Verf.-Referat L2 - https://dx.doi.org/10.1055/s-2007-1024900 DO - 10.1055/s-2007-1024900 SP - S. 197-201 SN - 0172-4622 JO - International journal of sports medicine IS - 3 VL - 10 M3 - Gedruckte Ressource M3 - Elektronische Ressource (online) ID - PU199205052803 ER -