The reproducibility of submaximal work heart rates - an interim report
Deutscher übersetzter Titel: | Die Reproduzierbarkeit der Herzfrequenz bei submaximaler Arbeit - Ein Zwischenbericht |
---|---|
Autor: | Sykes, K.; Page, E.; Charlesworth, E.J. |
Erschienen in: | British journal of sports medicine |
Veröffentlicht: | 10 (1976), 2, S. 67-70, 4 Darst. |
Format: | Literatur (SPOLIT) |
Publikationstyp: | Zeitschriftenartikel |
Medienart: | Gedruckte Ressource |
Sprache: | Englisch |
ISSN: | 0306-3674, 1473-0480 |
Schlagworte: | |
Online Zugang: | |
Erfassungsnummer: | PU197800023656 |
Quelle: | BISp |
Abstract
Work heart rates were taken from four subjects performing standardized bouts of work on the Monark Ergometer. Whilst a linear relationship was observed between heart rate and work intensity on any one day, it is evident that day to day variations in the position (intercept) of these lines exists. The slopes are virtually identical for all subjects and for different days, however the position of the lines differs widely both between and within subjects. The best linear regression equation developed for the prediction of heart rate after 180 secondsofwork from preexercise heart rate and work intensity was found to have 95 conficence limits of +/- 12.7 beats. Heart rates are reproducible 95 of the time to within +/- 12.2 beats when pre-exercise heart rate is ignored. Verf.-Referat