Possibility of analytical finding of glycerol caused by self-catheterization in doping control

Gespeichert in:
Bibliographische Detailangaben
Deutscher übersetzter Titel:Möglichkeit des Auffindens von Glycerin im Analyseergebnis aufgrund von Selbstkatheterisierung bei der Dopingkontrolle
Autor:Okano, Masato; Nishitani, Yasunori; Kageyama, Shinji
Erschienen in:Drug testing and analysis
Veröffentlicht:6 (2014), 11/12 (32nd Cologne workshop: Advances in sports drug testing), S. 1151-1154, Lit.
Format: Literatur (SPOLIT)
Publikationstyp: Zeitschriftenartikel
Medienart: Elektronische Ressource (online) Gedruckte Ressource
Sprache:Englisch
ISSN:1942-7603, 1942-7611
DOI:10.1002/dta.1701
Schlagworte:
Online Zugang:
Erfassungsnummer:PU201504002636
Quelle:BISp

Abstract

Glycerol is listed on the World Anti-Doping Agency (WADA) prohibited list as a masking agent principally because the administration of glycerol increases plasma volume and decreases the concentration of haemoglobin and the value of haematocrit in blood. Glycerol is a naturally occurring substance; therefore, the threshold is set as 1.0 mg/mL in the WADA technical document (WADA TD2013DL). In a WADA-accredited doping control laboratory, three doping control urine specimens collected from impaired athletes were determined to contain a high concentration of glycerol (>1.0 mg/mL); two of these specimens were considered adverse analytical findings (AAFs). Self-catheterization is necessary for athletes with neurological disorders such as neurogenic bladder dysfunction. We conducted a simple simulation of self-catheterization as an experimental test using urethral catheters with an antiseptic agent containing glycerol to confirm the influence of this antiseptic agent on the quantitative value of glycerol in doping control analysis. Some users employ a catheter with glycerol solution (ca. 1 mL) to avoid pain during use. The urine sample passed through such a catheter exhibited a glycerol concentration (4.94 mg/mL) greater than the threshold level. In September 2014, the threshold for glycerol will change from 1.0 to 4.3 mg/mL (WADA TD2014DL); however, a possibility exists for the quantitative value of glycerol in doping control analysis to exceed the threshold because of the use of an antiseptic agent containing glycerol for self-catheterization. The AAF for glycerol for impaired athletes, particularly those who participate in Paralympic sports, should account for the use of a catheter with glycerol. Verf.-Referat