Comparison of three maximal anaerobic running test protocols in marathon runners, middle-distance runners and sprinters

Gespeichert in:
Bibliographische Detailangaben
Deutscher übersetzter Titel:Vergleich von drei Testprotokollen fuer den maximalen anaeroben Lauftest fuer Marathon-, Mittelstrecken- und Kurzstreckenlaeufer
Autor:Vuorimaa, T.; Häkkinen, K.; Vaehaesoeyrinki, P.; Rusko, H.
Erschienen in:International journal of sports medicine
Veröffentlicht:17 (1996), Suppl. 2, S. S109-S113, Lit.
Format: Literatur (SPOLIT)
Publikationstyp: Zeitschriftenartikel
Medienart: Gedruckte Ressource
Sprache:Englisch
ISSN:0172-4622, 1439-3964
Schlagworte:
Online Zugang:
Erfassungsnummer:PU199607109368
Quelle:BISp

Abstract des Autors

Three modifications of the maximal anaerobic running test (MART) were compared in sprinters (Spr, n=5), middle-distance runners (Mid, n=5) and marathon runners (Mar, n=6). The MART1, MART3 and MART5 consisted of n sets of 1 x 20-s, 3 x 20-s and 5 x 20-s runs, respectively, on a treadmill with 40-s recovery between the runs and 100-s recovery between the sets. In each MART the velocity of the first set of runs was 3.0 m/s and the slope 5. Thereafter, the velocity was gradually increased by 0.38 m/s for each consecutive set until exhaustion. After each set and after exhaustion fingertip blood samples were taken to determine lactate concentration and three counter-movement jumps (CMJ) were performed. Maximal (Pmax) and submaximal (P-4mM) running power in each MART was expressed as the oxygen demand (ml/kg/min) of the runs. In MART-1, Mar had a significantly lower Pmax than Mid or Spr (mean+/-SD; 97.8+/-5.4 vs. 121.0+/-4.4 vs. 119.2+/-5.4 ml/kg/min), while in MART-3 the groups did not differ significantly, and the sprinters were unable to perform MART-5. Mar, Mid and Spr attained the lower Pmax the more runs per set in MART (p<0.01). Mar had the higher peak blood lactate the more runs each set consisted of (p<0.001). In Mid and Spr, the peak blood lactate did not differ significantly between the MARTs but was significantly higher than the corresponding peak blood lactate of the marathon runners. Pmax in MART-1 correlated positively with maximal 20-m sprinting speed on a track and with CMJ height (p<0.001, n=16) but negatively with VO2max (p<0.001, n=16) while in MART-3 no significant correlations were found. It was concluded that the n x 1 x 20-s protocol should be used to measure the maximal anaerobic power of all runners. However, in long-distance runners more runs per set may be needed to evaluate their anaerobic capacity. Verf.-Referat