Energy consumption in paraplegic ambulation using the reciprocating gait orthosis and electric stimulation of the tigh muscles

Gespeichert in:
Bibliographische Detailangaben
Deutscher übersetzter Titel:Energieverbrauch von Paraplegikern beim Gehen mit Hilfe einer reziprok wirksamen Gangapparatur mit Elektrostimulation der Hueftmuskeln
Autor:Hirokawa, Shunji; Grimm, Matthew; Le, Thanh; Solomonow, Moshe; Baratta, Richard V.; Shoji, Hiromu; D`Ambrosia, Robert D.
Erschienen in:Archives of physical medicine and rehabilitation
Veröffentlicht:71 (1990), 9, S. 687-694, Lit.
Format: Literatur (SPOLIT)
Publikationstyp: Zeitschriftenartikel
Medienart: Gedruckte Ressource
Sprache:Englisch
ISSN:0003-9993, 1532-821X
Schlagworte:
Online Zugang:
Erfassungsnummer:PU199102046992
Quelle:BISp

Abstract

The energy consumption of 6 thoracic paraplegic persons ambulating in the reciprocating gait orthosis (RGO) with and without functional electric stimulation (FES) of their thigh muscles was determined as a function of walking speed. Plots of Kcal/kg-min and Kcal/kg-m vs walking speed in the RGO and RGO FES were experimentally determined in this study and compared with the energy cost of walking in the long leg brace (LLB), the hip guidance orthosis (HGO), and an FES walking aid from data available in the literature. The RGO FES required the lowest energy expenditure in Kcal/kg-m across the full range of walking speeds. The RGO, HGO, LLB, and FES walking orthoses ranked second, third, fourth, and fifth respectively. The lowest energy costs in Kcal/kg-min were associated with the RGO FES, followed by the RGO, HGO, LLB, and FES for walking speeds below .28m/sec. At walking speeds higher than .28m/sec the HGO demonstrates lower energy cost followed by the RGO FES, RGO, FES, and LLB. At the end of a 30-m walk, patients using the RGO FES had a mean heart rate (HR) which was 12 beats/min less than the mean HR when using the RGO without FES, 31 beats/min less than the HR when using the LLB, and 42 beats/min less than the HR when using FES only. It was concluded that the FES-powered RGO combines the advantages of a passive mechanical orthosis with those of FES to provide substantial improvements in energy cost which may provide paraplegic persons with a mode of independent ambulation superior to the wheelchair. Verf.-Referat